Eave and Gable Extensions

MVF-MVP Gable Ext Tail End w FSP Soffit

* NOTE: THIS FASTENER MUST NOT HIT THE PURLIN. ** FIELD CUT AROUND PURLINS FOR ATTACHMENT.

PANEL CLIP WITH FASTENERS (TYP.) PRE-GLUED THERMAL SPACER FOR GABLE EXTENSION (NOT BY CHIEF) IF SUB-FRAMING AT GABLE EXTENSION EXCEEDS 4'-0 SPACING THEN AN A-20 ANGLE WILL BE SENT AND FIELD CUT AROUND PURLINS FOR ATTACHMENT. FASTENERS FOR ANGLE TO PURLIN AND SOFFIT TO ANGLE WILL BE SENT. CHANGE ANGLE AND FASTENERS TO "DIM" LAYER.

1

PURLIN

GABLE EXTENSION DIMENSION

PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.

PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)

CLOSURE CLIPS (GCC-1) (TYP.)

BL

PURLIN CLOSURE (TYP.)

#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR) * 1/4-14 X 1 1/4" WT (12" C.C.) DOUBLE BEAD TAPE MASTIC DOUBLE BEAD TAPE MASTIC

#12-14 x 1" PANCAKE HEAD (AT EACH PURLIN PRIOR TO SOFFIT INSTALLATION (TYP.) GABLE EXTENSION CHANNEL (GEC) EXTENSION FLASHING (EF) 1/4-14 X 7/8" (12" C.C.) GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) GABLE EXPANSION TRIM (GET) 1/8" X 3/8" BLIND RIVET (12" C.C.) FSP SOFFIT PANEL GABLE TRIM (GTV) RAKE ANGLE (A-20-B) (2) #12-14 X 1 1/4" (WALL COLOR) EACH CLIP CLIP LOCATION FROM S L #12-14 X 1 1/4" (12" C.C.) (TRIM COLOR) (2) 1/4-14 X 7/8" ROOF PANEL CUT BACK DIM.

1 3 4 "

PURLIN

1"

MVF/MVP ROOF PANEL ** RAKE ANGLE (A-20) #12-14 X 1" (PANCAKE HEAD (12" C.C.) (TYP.)

PURLIN

****DRAFTING NOTE: THERMAL SPACER TO BE USED WITH NO INSULATION

PURLIN CLOSURE (GPC)

(2) 1/8" X 3/8" BLIND RIVETS (TYP.)

****

PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQ'D) (2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN #12-14 X 1 1/4" AT EACH PURLIN ROW (WALL COLOR) PRE-GLUED THERMAL SPACER (NOT BY CHIEF)

(2) #12-14 X 1 1/4"' PER CLOSURE

TOP VIEW

1/4-14 X 7/8" (EACH RIB) (SOFFIT COLOR)

NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.

1/4-14 X 7/8" (EACH RIB) (SOFFIT COLOR)

#12-14 X 1" PANCAKE HEAD (12" C.C.) #12-14 X 1" PANCAKE HEAD (AT EACH PURLIN PRIOR TO SOFFIT INSTALLATION) 1/8" X 3/8" BLIND RIVET (12" C.C.)

#12-14 X 1 1/4" (6 " C.C. for CS PANEL) (12" C.C. for AP PANEL)

EAVE STRUT

*** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS

INSIDE CLOSURE ***

(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)

WITH LINER INSULATION SYSTEM.

PANEL CAP TRIM (SCT) RAKE ANGLE (A-20-B)

JAMB TRIM/SOFFIT TRIM (JTS)

1/4-14 X 7/8" (12" C.C.)

PURLIN CLOSURE INSTALLATION

WALL PANEL

Made with FlippingBook flipbook maker