Eave and Gable Extensions
CS Low Side Eave Ext w Oversize Gutter FSP Soffit
CS ROOF PANEL
TAPE MASTIC AT PANEL LAP
1
1/4-14 X 1 1/4" WT (6" C.C.)
NOTE: IF INTERMEDIATE PURLIN IS REQUIRED, CHG PURLIN AND ALL FASTENERS TO "DIM" LAYER.
(1) 1/4-14 X 7/8" (TRIM COLOR) GUTTER STRAP (GSO) (1'-0" C.C.) 1/4-14 X 7/8" WT (6" C.C.) * INSIDE CLOSURE WITH TAPE MASTIC TOP & BOTTOM ** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.
(2) 1/4-14 X 1 1/4" WT EACH STRAP INSIDE CLOSURE
8 11
16 "
BL
2 3
4 "
1/4-14 X 1 1/4" WT (__" C.C.)
1/4-14 X 1 1/4" WT (6" C.C.) (2) 1/4-14 X 7/8" WT EACH STRAP
PIGTAIL TAPE MASTIC (Install a "Pig Tail" down the bearing leg of panel to form a continuous line of tape mastic with panel lap and closure.)
1/4-14 X 7/8" (12" C.C.) (SOFFIT COLOR)
CS ROOF PANEL
1/4-14 X 7/8" WT (6" C.C.)
1"
CS INSIDE CLOSURE
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) 1/4-14 X 1 1/4" WT (6" C.C.)
TAPE MASTIC ON TOP OF CLOSURE
**
OVERSIZED GUTTER (EGAO)
OVERSIZED EAVE GUTTER (EGAO)
INSIDE CLOSURE
#12-14 X 1 1/4" (12" C.C.) (TRIM COLOR)
1/4-14 X 7/8" (12" C.C.) (SOFFIT COLOR) OUTSIDE CLOSURE
FSP SOFFIT PANEL # 12-14 X 1" PANCAKE HEAD (12" C.C.)
1/8"X 3/8" BLIND RIVET (12" C.C.) 1/4-14 X 7/8" (12" C.C.) EXTENSION FLASHING (EF) EAVE EXTENSION FLASHING (EEFA)
TAPE MASTIC ON BOTTOM OF CLOSURE
EAVE MEMBER EXTENSION FLASHING (EF)
#12-14 X 1" PANCAKE HEAD (12" C.C.) (TYP.)
SOFFIT TRIM (SBLTO) 1/8" X 3/8" BLIND RIVET (12" C.C.)
CS INSIDE CLOSURE
1/4-14 X 7/8" (EACH RIB) (SOFFIT COLOR)
EAVE EXTENSION FLASHING (EEFA)
WALL PANEL
* See isometric detail "PIGTAIL TAPE MASTIC INSTALLATION WITH OVERSIZED EAVE GUTTER AT EAVE EXTENSION".
PIGTAIL TAPE MASTIC INSTALLATION WITH OVERSIZED EAVE GUTTER AT EAVE EXTENSION
Made with FlippingBook flipbook maker