Eave and Gable Extensions
Eave Ext Horiz Soff Low Gable Ext - FSP Soffit Bypass Gable and CS Roof Low Pitch
REFER TO GABLE SECTIONS FOR ROOF PANEL AND GABLE TRIM ATTACHMENTS AT THE BUILDING GABLE. *** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.
Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
* (2) #12-14 X 1 1/4" ON TOP AND (1) #12-14 X 1 1/4" ON BOTTOM (WALL COLOR) HOLD 1" DISTANCE
1
GABLE EXTENSION CHANNEL (GEC)
INSIDE CLOSURE
***
INTERMEDIATE PURLIN
BL
#12-14 X 1 1/4" (TYP) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
* 1"
FRAMING CONDITION NOT SHOWN
EAVE EXTENSION END PANEL
#12-14 X 1" PANCAKE HEAD (24" C.C.)
SOFFIT RAKE ANGLE (A-20) ** INSIDE CLOSURE
XXX' - X"
1
4 "
SOFFIT TRIM (VPST)
EAVE EXTENSION BEAM FSP SOFFIT PANEL #12-14 X 1" PANCAKE HEAD (12" C.C.) (TYP.)
1/8" X 3/8" BLIND RIVET (12" C.C.) PANEL SUPPORT (SSSP) **DRAFTING: INSIDE CLOSURE NOT REQ'D IF WALLS ARE "CS INSULATED"