Eave and Gable Extensions

LS Eave Ext Only - Horiz FSP Soffit Bypass Gable and CS Roof Panel Low Pitch

REFER TO GABLE SECTIONS FOR ROOF PANEL AND GABLE TRIM ATTACHMENTS AT THE BUILDING GABLE. *** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.

Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

* (2) #12-14 X 1 1/4" ON TOP AND (1) #12-14 X 1 1/4" ON BOTTOM (WALL COLOR) HOLD 1" DISTANCE

1

GABLE EXTENSION CHANNEL (GEC)

INSIDE CLOSURE

***

INTERMEDIATE PURLIN

BL

#12-14 X 1 1/4" (TYP) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

* 1"

FRAMING CONDITION NOT SHOWN

EAVE EXTENSION END PANEL

#12-14 X 1" PANCAKE HEAD (24" C.C.)

SOFFIT RAKE ANGLE (A-20) INSIDE CLOSURE **

XXX' - X"

1

4 "

SOFFIT TRIM (VPST)

EAVE EXTENSION BEAM FSP SOFFIT PANEL #12-14 X 1" PANCAKE HEAD (12" C.C.) (TYP.)

1/8" X 3/8" BLIND RIVET (12" C.C.) PANEL SUPPORT (SSSP) **DRAFTING: INSIDE CLOSURE NOT REQ'D IF WALLS ARE "CS INSULATED"