Eave and Gable Extensions

LS Eave Ext Only - Horiz FSP Soffit-CS-Eave Gutter

1

BL

CS ROOF PANEL * 1/4-14 X 1 1/4" WT (__" C.C.) (TYP.) * 12" C.C. NON UL 6" C.C. UL 90

(1) 1/4-14 X 7/8" (TRIM COLOR) GUTTER STRAP (GS) (___" C.C.) 1/4-14 X 7/8" WT (6" C.C.) INSIDE CLOSURE WITH TAPE MASTIC TOP & BOTTOM

1/4-14 X 1 1/4" WT (6" C.C.) (2) 1/4-14 X 7/8" WT EACH GUTTER STRAP INSIDE CLOSURE

8 11

16 "

1/4-14 X 1 1/4" WT (6" C.C.)

2 7 8 "

EAVE STRUT

SOFFIT PURLIN

EAVE GUTTER (EGA)

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

(2) 1/4-14 X 1 1/4" WT EACH GUTTER STRAP

INSIDE CLOSURE **

#12-14 X 1 1/4" (12" C.C.) (TRIM COLOR) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

OUTSIDE CLOSURE INTERMEDIATE PURLIN

TRIM CAP (TC_)

SPECIAL TRIM (SPT- ) EAVE EXTENSION PURLIN

1/4-14 X 7/8" (12" C.C.) (SOFFIT COLOR)

#12-14 X 1" PANCAKE HEAD (12" C.C.) (TYP.) FSP SOFFIT PANEL

SOFFIT TRIM (SBLTA)

1/8" X 3/8" BLIND RIVET (12" C.C.)

WALL PANEL

NOTE: 26 GA FSP SOFFIT MUST HAVE 1/4-14 X 7/8" FASTENERS AT HI-RIB, LOCATED AT SUPPORTS AND MID-SPAN BETWEEN SUPPORTS. SHOW AND CALL OUT FASTENER IF REQUIRED.

NOTE: SOFFIT PURLIN SHOWN REMOVE IF NOT USED. TURN SPECIAL ANGLE FASTENER & TEXT TO BE VISIBLE.

SPECIAL ANGLE (PL )

** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.

Made with FlippingBook flipbook maker