Eave and Gable Extensions
Eave Ext Horiz Soff Low STC-MSC - FSP Soffit w Gutter
1
PRE-GLUED THERMAL SPACER (NOT BY CHIEF)
1/4-14 X 1" (2) PER CLOSURE METAL INSIDE CLOSURE (2) 1/4-14 X 7/8" WT GUTTER STRAP TO ROOF PANEL
BL
* SEE ADJACENT DETAIL FOR INSTALLATION OF TRAPEZOID PLUG (TRP) ** FIELD CUT (2) 2" LONG STRIPS OF TRI-BEAD TAPE SEALER. CENTER UNDER 1/4-14 X 7/8" WT FASTENERS BETWEEN GUTTER STRAP AND ROOF PANEL. *** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM. NOTE: 26 GA FSP SOFFIT MUST HAVE 1/4-14 X 7/8" FASTENERS AT HI-RIB, LOCATED AT SUPPORTS AND MID-SPAN BETWEEN SUPPORTS. SHOW AND CALL OUT FASTENER IF REQUIRED. NOTE: SOFFIT PURLIN SHOWN REMOVE IF NOT USED. TURN SPECIAL ANGLE FASTENER & TEXT TO BE VISIBLE.
PANEL CLIP WITH FASTENERS
1/4-14 X 1 1/4" WT (8 PER PANEL)
STC/MSC ROOF PANEL
3 3
DOUBLE BEAD TAPE MASTIC * TRAPEZOID PLUG (TRP) EACH HIGH RIB TRI-BEAD TAPE SEALER
8 "
1/4-14 X 1 1/4" WT (6 PER PANEL)
** 2" STRIP TRI-BEAD TAPE SEALER (TYP.)
EAVE STRUT
GUTTER STRAP (GSM) AT EACH PANEL HI-RIB
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
#12-14 X 1 1/4" (TRIM COLOR)
INSIDE CLOSURE
***
EAVE GUTTER (EGM) 1/4-14 X 7/8" WT 6" C.C.)
1/4-14 X 7/8" (12" C.C.) (SOFFIT COLOR) OUTSIDE CLOSURE
1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
#12-14 X 1 1/4" (12" C.C.) (TRIM COLOR)
SOFFIT PURLIN
INTERMEDIATE PURLIN
FSP SOFFIT PANEL
TRIM CAP (TC_)
SOFFIT TRIM (SBLTA)
#12-14 X 1" PANCAKE HEAD (12" C.C.) (TYP.) EAVE EXTENSION PURLIN
SPECIAL TRIM (SPT- ) 1/8" X 3/8" BLIND RIVET (12" C.C.) (TYP.)
WALL PANEL
SPECIAL ANGLE (PL )
Made with FlippingBook flipbook maker