Eave and Gable Extensions
STC-MSC Low Side Eave Ext w Eave Gutter and CS-AP Soffit and Thermal Spacer
1/4-14 X 1 1/4" WT (8 PER PANEL)
** (2) 1/4-14 X 7/8" WT GUTTER STRAP TO ROOF PANEL
PRE-GLUED THERMAL SPACER FOR EAVE EXTENSION (NOT BY CHIEF) PANEL CLIP W/ FASTENERS (SEE ROOF PANEL PLAN)
BL
METAL INSIDE CLOSURE TRI-BEAD TAPE MASTIC (TOP AND BOTTOM) 2" STRIP OF TRI-BEAD TAPE MASTIC BETWEEN PANELS
1/4-14 X 7/8" WT (6" C.C.) DOUBLE BEAD TAPE MASTIC (TOP AND BOTTOM) * TRAPEZOID PLUG (TRP) AT EACH HIGH RIB GUTTER STRAP (GSM) AT PANEL HI-RIBS #12-14 X 1 1/4" (TRIM COLOR)
STC/MSC ROOF PANEL
1/4-14 X 1 1/4" WT (6 PER PANEL)
EAVE GUTTER (EGM)
INTERMED. PURLIN ****
EAVE EXTENSION FLASHING (EEFA)
1/4-14 X 7/8" (12" C.C.) (SOFFIT COLOR) SOFFIT TRIM (ESTO) 1/4-14 X 7/8" (12" C.C.) WALL PANEL OUTSIDE CLOSURE INSIDE CLOSURE *** #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
#12-14 X 1 14" (12" C.C.) (TRIM COLOR) 1/4-14 X 7/8" (12" C.C.)
#12-14 X 1 1/4" (12" C.C.) SOFFIT PANEL 1/4-14 X 1" (2 PER CLOSURE)
EXTENSION FLASHING (EF)
PANEL OVERHANG
GUTTER STRAP LAP
PITCH
1/4-14 X 7/8" (12" C.C.)
<=3/4:12 >3/4:12 to <=1 1/2:12 >1 1/2:12 to <=2 1/2:12 >2 1/2:12 to <=3 1/2:12 >3 1/2:12 to <=4 1/2:12 ALL DIMENSIONS IN INCHES 4 1/2 3 1/2 3 1/2 4 4 1/4
7 7/8 7 1/2
OUTSIDE CLOSURE
7 1/8
6 7/16
5 3/4
DRAFTING NOTES: ***
** Field cut (2) 2" long strips of tri-bead tape mastic & center under 1/4-14 x 7/8" WT's between gutter strap and roof panel. * See isometric Trapezoid Plug Installation detail for installation instructions.
Inside closure must be provided on buildings with liner insulation system. **** If intermediate purlin is required, chg purlin, t-spacer and all fasteners to "dim" layer.