STC-MSC High Side Eave Ext w Eave Trim and CS-AP Soffit and Thermal Spacer

1/4-14 X 1 1/4" WT (9 PER PANEL) OUTSIDE CLOSURE

*1/4-14 X 7/8" WT TRI-BEAD TAPE MASTIC

3 1

BL

PRE-GLUED THERMAL SPACER FOR EAVE EXTENSION

PRE-GLUED THERMAL SPACER PANEL CLIP W/ FASTENERS (SEE ROOF PANEL PLAN) (TYP)

2 "

**TRI-BEAD TAPE MASTIC

(NOT BY CHIEF)

STC/MSC ROOF PANEL

BACK-UP PLATE

(NOT BY CHIEF)

#12-14 X 1 1/4" (12" C.C.) (TRIM COLOR)

INTERMED. PURLIN ****

HI-SIDE EAVE TRIM (HETM)

1/4-14 X 7/8" (12" C.C.) (SOFFIT COLOR) OUTSIDE CLOSURE SOFFIT TRIM (ESTA) 1/4-14 X 7/8" (12" C.C.) WALL PANEL #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) INSIDE CLOSURE *** THERMAL SPACER

(NOT BY CHIEF)

1/4-14 X 7/8" (12" C.C.)

HIGH SIDE EXTENSION FLASHING (HEEF)

SOFFIT PANEL

1/4-14 X 7/8" (12" C.C.)

#12-14 X 1 1/4" (12" C.C.)

OUTSIDE CLOSURE

DRAFTING NOTES: *** Inside closure must be provided on buildings with liner insulation system. **** If intermediate purlin is required, chg purlin, t-spacer and all fasteners to "dim" layer.

* For screw spacing refer to High Eave Trim detail in the MSC/STC Roof Panel Erection Manual. ** 24" STC - Pre-Cut Tri-Bead Tape Mastic. 24" MSC - Tri-Bead Tape Mastic from roll. 18" MSC/STC - Tri-Bead Tape Mastic from roll.