Eave and Gable Extensions

STC-MSC High Side Eave Ext w Eave Trim and NO Soffit and Thermal Spacer

*1/4-14 X 7/8" WT TRI-BEAD TAPE MASTIC

1/4-14 X 1 1/4" WT (9 PER PANEL) OUTSIDE CLOSURE **TRI-BEAD TAPE MASTIC

STC/MSC ROOF PANEL *** TRAPEZOID PLUG (TRP) AT EACH HI-RIB PRE-GLUED THERMAL SPACER FOR EAVE EXTENSION

(NOT BY CHIEF)

BL

3 1

2 "

PANEL CLIP W/ FASTENERS (SEE ROOF PANEL PLAN) (TYP)

PRE-GLUED THERMAL SPACER

(NOT BY CHIEF)

BACK-UP PLATE

THERMAL SPACER

(NOT BY CHIEF)

HI-SIDE EAVE TRIM (HETM)

INTERMED. PURLIN *****

1/8" X 3/8" BLIND RIVET (PARCHMENT) (2 PER PLUG)

1/4-14 X 7/8" (12" C.C.) HIGH SIDE EXTENSION FLASHING (HEEF)

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

#12-14 X 1 1/4" (12" C.C.) (TRIM COLOR)

INSIDE CLOSURE ****

DRAFTING NOTES: **** Inside closure must be provided on buildings with liner insulation system. ***** If intermediate purlin is required, chg purlin, t-spacer and all fasteners to "dim" layer.

1/4-14 X 7/8" (12" C.C.)

NOTE: Jamb trim around extension beam as required. * For screw spacing refer to High Eave Trim detail in the MSC/STC Roof Panel Erection Manual. ** 24" STC - Pre-Cut Tri-Bead Tape Mastic. 24" MSC - Tri-Bead Tape Mastic from roll. 18" MSC/STC - Tri-Bead Tape Mastic from roll.

PANEL CAP TRIM (SCT)

WALL PANEL

*** See isometric Trapezoid Plug Installation detail for installation instructions.