Eave and Gable Extensions

STC-MSC Gable Ext Lead End w CS Soffit

***DRAFTING NOTE: THERMAL SPACER TO BE USED WITH NO INSULATION

* NOTE: IT IS IMPORTANT THAT 1/4-14 X 1 1/4" SHOULDER FASTENERS ARE INSTALLED THROUGH THE CENTER OF THE SLOTTED HOLES OF THE RAKE SUPPORT.

PURLIN

PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.

PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)

CLOSURE CLIPS (GCC-1) (TYP.)

PURLIN CLOSURE (TYP.)

PANEL CLIP W/FASTENERS

#12-14 X 1 1/4" (12" C.C.) (TRIM COLOR) * 1/4-14 X 1 1/4" SHOULDER (24" C.C.) RAKE SUPPORT (A-20-S) GABLE TRIM (GTM)

PURLIN

1

PURLIN CLOSURE (GPC) PRE-GLUED THERMAL SPACER *** (NOT BY CHIEF) PRE-GLUED THERMAL SPACER FOR GABLE EXTENSION (NOT BY CHIEF)

GABLE EXTENSION DIMENSION

BL

PURLIN

TRI-BEAD TAPE SEALER 1/4-14 X 1 1/4" WT (12" C.C.)

(2) 1/8" X 3/8" BLIND RIVETS (TYP.)

#12-14 X 1" PANCAKE HEAD (2 PER PURLIN)

STC/MSC ROOF PANEL

(2) #12-14 X 1 1/4"' PER CLOSURE

PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQ'D) (2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN #12-14 X 1 1/4" AT EACH PURLIN ROW (WALL COLOR)

(2) 1/4-14 X 7/8

TOP VIEW

GABLE TRIM SUPPORT (GTS) (10'-0" C.C.)

GABLE EXPANSION TRIM (GET)

CS SOFFIT PANEL 1/4-14 X 7/8" (12" C.C.) JAMB TRIM (JT)

1/4-14 X 7/8" (12" C.C.) EXTENSION FLASHING (EFC) GABLE EXTENSION CHANNEL (GEC) #12-14 X 1" PANCAKE HEAD EACH PURLIN

NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

EAVE STRUT

1/4-14 X 7/8 (12" C.C.)

INSIDE CLOSURE **

** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.

(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)

PANEL CAP TRIM (SCT) RAKE ANGLE (A-20-B)

#12-14 X 1 1/4" (12" C.C.)

WALL PANEL

PURLIN CLOSURE INSTALLATION

Made with FlippingBook flipbook maker