Eave and Gable Extensions

STC-MSC Gable Ext Tail End-Field Bend Vertical Leg-Term Trim w AP Soffit

***DRAFTING NOTE: THERMAL SPACER TO BE USED WITH NO INSULATION

* NOTE: IT IS IMPORTANT THAT 1/4-14 X 1 1/4" SHOULDER FASTENERS ARE INSTALLED THROUGH THE CENTER OF THE SLOTTED HOLES OF THE RAKE SUPPORT.

PURLIN

1

PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.

PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)

TRI-BEAD TAPE SEALER 1/4-14 X 7/8" WT (6" C.C.) TERMINATION TRIM (GTTM) 1/4-14 X 1 1/4" WT (24" C.C.) NOTE: FIELD FORM A 3" VERTICAL ROOF PANEL LEG TO FIT FINAL DIMENSION

GABLE EXTENSION DIMENSION

CLOSURE CLIPS (GCC-1) (TYP.)

PURLIN CLOSURE (TYP.)

BL

TRI-BEAD TAPE SEALER 1/4-14 X 1 1/4" WT (12" C.C.) * 1/4-14 X 1 1/4 SHOULDER (24" C.C.) STC/MSC ROOF PANEL RAKE ANGLE (A-20-B) #12-14 X 1" PANCAKE HEAD (2 PER PURLIN) RAKE SUPPORT (A-20-S)

PANEL CLIP w/FASTENERS

PURLIN

PURLIN

PRE-GLUED THERMAL SPACER FOR GABLE EXTENSION (NOT BY CHIEF)

PURLIN CLOSURE (GPC)

GABLE TRIM (GTM)

(2) 1/8" X 3/8" BLIND RIVETS (TYP.)

#12-14 X 1 1/4" AT EACH PURLIN ROW (WALL COLOR) PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQ'D) (2)1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN PRE-GLUED THERMAL SPACER *** (NOT BY CHIEF)

#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN) * 1/4-14 X 1 1/4 SHOULDER (24" C.C.) RAKE SUPPORT (A-20-S)

(2) #12-14 X 1 1/4"' PER CLOSURE

TOP VIEW

#12-14 X 1 1/4" (12" C.C.) (TRIM COLOR) 1/4-14 X 7/8" (12" C.C.) GABLE TRIM SUPPORT (GTS) 10'-0" C.C.)

NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.

1/4-14 X 7/8" (12" C.C.) GABLE EXPANSION TRIM (GET)

AP SOFFIT PANEL

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

1/4-14 X 7/8" (12" C.C.) (SOFFIT COLOR)

EAVE STRUT

GABLE EXTENSION CHANNEL (GEC)

PANEL SUPPORT TRIM (SSP (TYP.) 1/4-14 X 7/8" (12" C.C.) (TYP.)

(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)

INSIDE CLOSURE **

#12-14 X 1 1/4" (12" C.C.) (SOFFIT COLOR) EXTENSION FLASHING (EF)

1/4-14 X 7/8" (12" C.C.) PANEL CAP TRIM (SCT) RAKE ANGLE (A-20-B)

JAMB TRIM (JT) ** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.

#12-14 X 1" PANCAKE HEAD EACH PURLIN

PURLIN CLOSURE INSTALLATION

WALL PANEL

Made with FlippingBook flipbook maker