Eave and Gable Extensions
STC-MSC Gable Ext Tail End-Termination Trim w CS Soffit
PURLIN
PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.
PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)
CLOSURE CLIPS (GCC-1) (TYP.)
PURLIN CLOSURE (TYP.)
STC/MSC ROOF PANEL PANEL CLIP w/FASTENERS (SEE ROOF PANEL PLAN)
BL
TRI-BEAD TAPE MASTIC 1/4-14 X 7/8" WT (6" C.C.) 1/4-14 X 1 1/4" WT(24" C.C.) RAKE SUPPORT (A-20-S)
GABLE EXTENSION DIMENSION
TRI-BEAD TAPE MASTIC 1/4-14 X 1 1/4" WT (12" C.C. AND FASTEN THROUGH CLIP) TERMINATION TRIM (GTTM) #12-14 X 1 1/4" PANCAKE HEAD EACH PURLIN
PURLIN
PRE-GLUED THERMAL SPACER FOR GABLE EXTENSION
(NOT BY CHIEF)
PURLIN
PURLIN CLOSURE (GPC)
GABLE TRIM (GTMC)
(2) 1/8" X 3/8" BLIND RIVETS (TYP.)
***PRE-GLUED THERMAL SPACER (NOT BY CHIEF)
#12-14 X 1 1/4" (12" C.C.) (TRIM COLOR) * 1/4-14 X 1 1/4" SHOULDER (24" C.C.) #12-14 X 1" PANCAKE HEAD (2 PER PURLIN)
(2) #12-14 X 1 1/4"' PER CLOSURE
#12-14 X 1 1/4" AT EACH PURLIN ROW (WALL COLOR) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQ'D) (2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN
TOP VIEW
(2) 1/4-14 X 7/8"
GABLE TRIM SUPPORT (GTS) (10'-0" C.C.)
CS SOFFIT PANEL 1/4-14 X 7/8" (12" C.C.) JAMB TRIM (JT) 1/4-14 X 7/8" (12" C.C.) PANEL CAP TRIM (SCT)
NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.
GABLE EXPANSION TRIM (GET)
1/4-14 X 7/8" (12" C.C.) GABLE EXTENSION CHANNEL (GEC)
EAVE STRUT
DRAFTING NOTES: ** Inside closure must be provided on buildings with liner insulation system. *** Thermal spacer to be used with no insulation.
(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)
INSIDE CLOSURE **
EXTENSION FLASHING (EFC)
RAKE ANGLE (A-20-B)
* It is important that 1/4-14 x 1 1/4" SHOULDER fasteners are installed through the center of the slotted holes of the rake support.
WALL PANEL
#12-14 X 1 1/4" (12" C.C.)
PURLIN CLOSURE INSTALLATION
Made with FlippingBook flipbook maker