Eave and Gable Extensions
STC-MSC Gable Ext Tail End -Field Bend Vertical Leg-Term Trim w AP Soffit and Thermal Spacer
PURLIN
GABLE EXTENSION DIMENSION
PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.
PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)
CLOSURE CLIPS (GCC-1) (TYP.)
TRI-BEAD TAPE SEALER 1/4-14 X 7/8" WT (6" C.C.) TERMINATION TRIM (GTTM) 1/4-14 X 1 1/4" WT (24" C.C.) NOTE: FIELD FORM A 3" VERTICAL ROOF PANEL LEG TO FIT FINAL DIMENSION
BL
TRI-BEAD TAPE SEALER 1/4-14 1 1/4" WT (12" C.C.) * 1/4-14 X 1 1 /4" SHOULDER (24" C.C.) RAKE ANGLE (A-20-B) #12-14 X 1" PANCAKE HEAD (2) PER PURLIN) RAKE SUPPORT (A-20-T) PRE-GLUED THERMAL SPACER FOR GABLE EXTENSION (NOT BY CHIEF)
PURLIN CLOSURE (TYP.)
* NOTE: It is important that 1/4-14 X 1 1/4" SHOULDER fasteners are installed through the center of the slotted holes of the rake support.
PANEL CLIP w/FASTENERS (SEE ROOF PANEL PLAN) STC/MSC ROOF PANEL
PURLIN
GABLE TRIM (GTMC)
(2) 1/8" X 3/8" BLIND RIVETS (TYP.)
PURLIN THERMAL SPACER
(NOT BY CHIEF)
(2) #12-14 X 1 1/4"' PER CLOSURE
RAKE SUPPORT (A-20-T)
* 1/4-14 X 1 1/4" SHOULDER(24" C.C.)
PURLIN CLOSURE (GPC)
#12-14 X 1 1/4" (12" C.C.) (TRIM COLOR) #12-14 X 1" PANCAKE HEAD (2 PER PURLIN)
PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQ'D) (2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN #12-14 X 1 1/4" AT EACH PURLIN ROW (WALL COLOR)
TOP VIEW
(2) 1/4-14 X 7/8"
GABLE TRIM SUPPORT (GTS) 10'-0" C.C.)
NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.
GABLE EXPANSION TRIM (GET)
AP SOFFIT PANEL
GABLE EXTENSION CHANNEL (GEC) 1/4-14 X 7/8" (12" C.C.)
EAVE STRUT
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
PANEL SUPPORT TRIM (SSP) (TYP.) 1/4-14 X 7/8" (12" C.C. (TYP.) 1/4-14 X 7/8" (12" C.C.) (SOFFIT COLOR) JAMB TRIM (JT)
(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)
#12-14 X 1 1/4" (12" C.C.) (SOFFIT COLOR) EXTENSION FLASHING (EF)
INSIDE CLOSURE **
1/4-14 X 7/8" (12" C.C.) PANEL CAP TRIM (SCT) RAKE ANGLE (A-20-B)
WALL PANEL
** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.
#12-14 X 1" PANCAKE HEAD EACH PURLIN
PURLIN CLOSURE INSTALLATION
Made with FlippingBook flipbook maker