Eave and Gable Extensions
STC-MSC Gable Ext Tail End -Field Bend Vertical Leg-Term Trim w FSP Soffit and Thermal Spacer
PURLIN
GABLE EXTENSION DIMENSION
PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.
PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)
CLOSURE CLIPS (GCC-1) (TYP.)
TRI-BEAD TAPE SEALER 1/4-14 X 7/8" WT (6" C.C.) TERMINATION TRIM (GTTM) 1/4-14 X 1 1/4" WT (24" C.C.) NOTE: FIELD FORM A 3" VERTICAL ROOF PANEL LEG TO FIT FINAL DIMENSION
BL
PURLIN CLOSURE (TYP.)
TRI-BEAD TAPE SEALER 1/4-14 X 1 1/4" WT (12" C.C.)
RAKE ANGLE (A-20-B) #12-14 X 1" PANCAKE HEAD (2 PER PURLIN) (TYP AT GEC) RAKE SUPPORT (A-20-T) * 1/4-14 X 1 1/4 SHOULDER (24" C.C.) PRE-GLUED THERMAL SPACER FOR GABLE EXTENSION (NOT BY CHIEF)
* NOTE: It is important that 1/4-14 X 1 1/4" SHOULDER fasteners are installed through the center of the slotted holes of the rake support.
PURLIN
PURLIN PANEL CLIP w/FASTENERS (SEE ROOF PANEL PLAN) STC/MSC ROOF PANEL THERMAL SPACER
(2) 1/8" X 3/8" BLIND RIVETS (TYP.)
GABLE TRIM (GTMC) RAKE SUPPORT (A-20-T)
(2) #12-14 X 1 1/4"' PER CLOSURE
(NOT BY CHIEF)
#12-14 X 1 1/4" AT EACH PURLIN ROW (WALL COLOR) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQ'D) (2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN PURLIN CLOSURE (GPC)
* 1/4-14 X 1 1/4 SHOULDER (24" C.C.) #12-14 X 1 1/4" (12" C.C.) TRIM COLOR)
TOP VIEW
GABLE TRIM SUPPORT (GTS) 10'-0" C.C.) 1/4-14 X 7/8" (12" C.C.)
GABLE EXPANSION TRIM (GET)
NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.
1/4-14 X 7/8" (12" C.C.)
#12-14 X 1" PANCAKE HEAD (12" C.C.) (TYP.)
#12-14 X 1" PANCAKE HEAD (AT EACH PURLIN PRIOR TO SOFFIT INSTALLATION EXTENSION FLASHING (EF) GABLE EXTENSION CHANNEL (GEC)
1/8" X 3/8" BLIND RIVET" (12" C.C.) #12-14 X 1" PANCAKE HEAD (AT EACH PURLIN PRIOR TO SOFFIT INSTALLATION (TYP.) JAMB TRIM/SOFFIT TRIM (JTS)
EAVE STRUT
RAKE ANGLE (A-20-B)
(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)
FSP SOFFIT PANEL
1/4-14 X 7/8" (12" C.C.) PANEL CAP TRIM (SCT)
1/8" X 3/8" BLIND RIVET (12" C.C.)
WALL PANEL
PURLIN CLOSURE INSTALLATION
Made with FlippingBook flipbook maker