High Profile Trim

STC-MSC Low Side Eave Ext w High Profile Eave Gutter and CS-AP Soffit

1/4-14 X 1 1/4" WT (8 PER PANEL)

1/4-14 X 7/8" WT (6" C.C.) DOUBLE BEAD TAPE MASTIC (TOP AND BOTTOM) * TRAPEZOID PLUG (TRP) AT EACH HIGH RIB GUTTER STRAP (GSMH) AT PANEL HI-RIBS #12-14 X 1 1/4" (TRIM COLOR) ** (2) 1/4-14 X 7/8" WT GUTTER STRAP TO ROOF PANEL

METAL INSIDE CLOSURE TRI-BEAD TAPE MASTIC (TOP AND BOTTOM) STC/MSC ROOF PANEL 2" STRIP OF TRI-BEAD TAPE MASTIC BETWEEN PANELS

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

BL

1/4-14 X 1 1/4" WT (6 PER PANEL)

INSIDE CLOSURE ***

1/4-14 X 7/8" (12" C.C.) (SOFFIT COLOR) OUTSIDE CLOSURE

EAVE GUTTER (EGMH)

EAVE EXTENSION FLASHING (EEFA)

EXTENSION FLASHING (EF) #12-14 X 1 1/4" (12" C.C.) (TRIM COLOR) 1/4-14 X 7/8" (12" C.C.)

SOFFIT TRIM (ESTO) 1/4-14 X 7/8" (12" C.C.) WALL PANEL

#12-14 X 1 1/4" (12" C.C.) 1/4-14 X 7/8" (12" C.C.) SOFFIT PANEL 1/4-14 X 1" (2 PER CLOSURE)

PANEL OVERHANG

GUTTER STRAP LAP

PITCH

9 8 3/4

<=3/4:12 >3/4:12 to <=1 1/2:12 >1 1/2:12 to <=2 1/2:12 >2 1/2:12 to <=3 1/2:12 >3 1/2:12 to <=4 1/2:12

5 5/8

5 11/16

5 11/16

8 1/2

** Field cut (2) 2" long strips of tri-bead tape mastic & center under 1/4-14 x 7/8" WT's between gutter strap and roof panel. * See isometric Trapezoid Plug Installation detail for installation instructions.

5 13/16

8

5 15/16

7 9/16

All Dimensions in Inches DRAFTING NOTE: *** Inside closure must be provided on buildings with liner insulation system .

Made with FlippingBook flipbook maker