High Profile Trim

STC-MSC Gable Ext Tail End High Profile Trim-Field Bend Leg-Term Trim AP Sof and Thermal Spacer

1

PURLIN

PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.

GABLE EXTENSION DIMENSION TRI-BEAD TAPE SEALER 1/4-14 X 1 1/4" WT (12" C.C.)

PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)

TRI-BEAD TAPE SEALER 1/4-14 X 7/8" WT (6" C.C.) GABLE TRIM (GTMH) RAKE SUPPORT (A-20-T) TERMINATION TRIM (GTTM) 1/4-14 X 1 1/4" WT (24" C.C.) NOTE: FIELD FORM A 3" VERTICAL ROOF PANEL LEG TO FIT FINAL DIMENSION * 1/4-14 X 1 1/4 SHOULDER(24" C.C.)

CLOSURE CLIPS (GCC-1) (TYP.)

BL

*NOTE:IT IS IMPORTANT THAT 1/4-14 X 1 1/4" SHOULDER FASTENERS ARE INSTALLED THROUGH THE CENTER OF THE SLOTTED HOLES OF THE RAKE SUPPORT.

PURLIN CLOSURE (TYP.)

RAKE ANGLE (A-20-B) #12-14 X 1" PANCAKE HEAD (2 PER PURLIN) RAKE SUPPORT (A-20-T) #12-14 X 1" PANCAKE HEAD EACH PURLIN (NOT BY CHIEF) PRE-GLUED THERMAL SPACER * 1/4-14 X 1 1/4 SHOULDER (24" C.C.)

PURLIN STC/MSC ROOF PANEL PURLIN CLOSURE (GPC) PANEL CLIP w/FASTENERS

PURLIN

?

(2) 1/8" X 3/8" BLIND RIVETS (TYP.)

THERMAL SPACER

(NOT BY CHIEF)

(2) #12-14 X 1 1/4"' PER CLOSURE

PANEL SUPPORT TRIM (SSP) (TYP.) PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQ'D) (2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN

#12-14 X 1 1/4" (12" C.C.) (TRIM COLOR) 1/4-14 X 7/8" (12" C.C.) GABLE TRIM SUPPORT (GTS) 10'-0" C.C.)

TOP VIEW

GABLE EXPANSION TRIM (GET)

NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.

1/4-14 X 7/8" (12" C.C.)

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C for AP PANEL)

#12-14 X 1" PANCAKE HEAD (2 PER PURLIN)

AP SOFFIT PANEL

EAVE STRUT

INSIDE CLOSURE ***

EXTENSION GABLE FLASHING (EGFA) GABLE EXTENSION CHANNEL (GEC) **

#12-14 X 1 1/4" AT EACH PURLIN ROW (WALL COLOR)

1/4-14 X 7/8" (12" C.C.) PANEL CAP TRIM (SCT) RAKE ANGLE (A-20-B)

(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)

1/4-14 X 7/8" (12" C.C.) (SOFFIT COLOR) JAMB TRIM (JT)

#12-14 X 1 1/4" (12"C.C.) (SOFFIT COLOR)

**

TRIM TYPE EGFA EFHP

PURLIN SIZE

L OR H SYSTEM

WALL PANEL

HIGH PROFILE TRIM-SOFFITED GABLE EXT STC/ MSC

*** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.

PURLIN CLOSURE INSTALLATION

8

HIGH HIGH

1/4-14 X 7/8" (12" C.C.) (TYP.)

EGFA = EXTENSION GABLE FLASHING EFHP = EXT. FLASHING HIGH PROFILE

10