High Profile Trim

STC-MSC Gable Ext Tail End High Profile Trim-Field Bend Leg-Term Trim NO Sof and Thermal Spacer

1

PURLIN

PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.

*NOTE:IT IS IMPORTANT THAT 1/4-14 X 1 1/4" SHOULDER FASTENERS ARE INSTALLED THROUGH THE CENTER OF THE SLOTTED HOLES OF THE RAKE SUPPORT.

PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)

GABLE EXTENSION DIMENSION

TRI-BEAD TAPE SEALER 1/4-14 X 7/8" WT (6" C.C.) * 1/4-14 X 1 1/4" SHOULDER (24" C.C.) RAKE SUPPORT (A-20-T) GABLE TRIM (GTMH) #12-14 X 1 1/4" (12" C.C.) (TRIM COLOR) TERMINATION TRIM (GTTM) 1/4-14 X 1 1/4" WT (24" C.C.) NOTE: FIELD FORM A 3" VERTICAL ROOF PANEL LEG TO FIT FINAL DIMENSION

CLOSURE CLIPS (GCC-1) (TYP.)

PURLIN CLOSURE (TYP.)

BL

TRI-BEAD TAPE SEALER 1/4-14 X 1 1/4" WT (12" C.C.) * 1/4-14 X 1 1/4" SHOULDER (24" C.C.) (NOT BY CHIEF) PRE-GLUED THERMAL SPACER

PANEL CLIP w/FASTENERS STC/MSC ROOF PANEL PURLIN #12-14 X 1" PANCAKE HEAD (2 EACH PURLIN)

PURLIN

?

#12-14 X 1" PANCAKE HEAD (2 PER PURLIN) RAKE ANGLE (A-20-B) #12-14 X 1 1/4" (12" C.C.) RAKE SUPPORT (A-20-T)

(2) 1/8" X 3/8" BLIND RIVETS (TYP.)

(2) #12-14 X 1 1/4"' PER CLOSURE

THERMAL SPACER

(NOT BY CHIEF)

PURLIN CLOSURE (GPC)

TOP VIEW

(2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN RAKE ANGLE (A-20-B) FIELD NOTCH AS REQUIRED AT EACH PURLIN ROW PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQ'D) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE WALL PANEL

(2) 1/4-14 X 7/8"

1/4-14 X 7/8" (12" C.C.) GABLE EXPANSION TRIM (GET) GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) #12-14 X 1" PANCAKE HEAD (2 PER PURLIN) GABLE EXTENSION CHANNEL (GEC)

NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.

**

INSIDE CLOSURE

EAVE STRUT

#12-14 X 1 1/4" (6" C.C. for CS PANEL ) (12" C.C. for AP PANEL) 1/4-14 X 7/8" (12" C.C.)

(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)

EF- EXTENSION FLASHING EFHP - EXTENSION FLASHING HIGH PROFILE

*** HIGH PROFILE TRIM UNSOFFITED GABLE EXT STC / MSC

TRIM TYPE

PURLIN SIZE

L OR H SYSTEM

#12-14 X 1" PANCAKE HEAD EACH PURLIN EXTENSION FLASHING (EF) ***

** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.

PURLIN CLOSURE INSTALLATION

PANEL CAP (SCT)

8

HIGH HIGH

EF

10

EFHP

Made with FlippingBook flipbook maker