High Profile Trim

STC-MSC Gable Ext Tail End High Profile Trim-Term Trim CS Soffit and Thermal Spacer

PURLIN

PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.

PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)

GABLE EXTENSION DIMENSION

CLOSURE CLIPS (GCC-1) (TYP.)

PURLIN CLOSURE (TYP.)

BL

* It is important that 1/4-14 x 1 1/4" SHOULDER fasteners are installed through the center of the slotted holes of the rake support.

TRI-BEAD TAPE MASTIC 1/4-14 X 1 1/4" WT (12" C.C.) #12-14 X 1" PANCAKE HEAD EACH PURLIN (NOT BY CHIEF) PRE-GLUED THERMAL SPACER

TRI-BEAD TAPE MASTIC 1/4-14 X 7/8" WT (6" C.C.) RAKE SUPPORT (A-20-T) #12-14 X 1" PANCAKE HEAD (2 PER PURLIN) TERMINATION TRIM (GTTM) 1/4-14 X 1 1/4" WT (24" C.C.) #12-14 X 1 1/4" (12" C.C.) (TRIM COLOR) GABLE TRIM (GTMH)

STC/MSC ROOF PANEL PANEL CLIP w/FASTENERS

?

PURLIN

PURLIN

(2) 1/8" X 3/8" BLIND RIVETS (TYP.)

#12-14 X 1 1/4" (12" C.C.)

THERMAL SPACER

(NOT BY CHIEF)

(2) #12-14 X 1 1/4"' PER CLOSURE

PURLIN CLOSURE (GPC)

PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQ'D) (2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN

TOP VIEW

(2) 1/4-14 X 7/8"

GABLE TRIM SUPPORT (GTS) (10'-0" C.C.)

GABLE EXPANSION TRIM (GET)

1/4-14 X 7/8" (12" C.C.)

NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.

CS SOFFIT PANEL 1/4-14 X 7/8" (12" C.C.)

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

* 1/4-14 X 1 1/4" SHOULDER (24" C.C.)

#12-14 X 1 1/4" AT EACH PURLIN ROW (WALL COLOR)

GABLE EXTENSION CHANNEL (GEC)

INSIDE CLOSURE **

EAVE STRUT

TRIM TYPE EGFA EFHP

PURLIN SIZE

L OR H SYSTEM

***

JAMB TRIM (JT)

1/4-14 X 7/8" (12" C.C.) PANEL CAP TRIM (SCT) RAKE ANGLE (A-20-B)

(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)

EXTENSION FLASHING (EFCP)

DRAFTING NOTES: ** Inside closure must be provided on buildings with liner insulation system. *** High profile trim soffited gable ext STC / MSC.

8

HIGH HIGH

10

EGFA = EXTENSION GABLE FLASHING EFHP = EXT. FLASHING HIGH PROFILE

WALL PANEL

PURLIN CLOSURE INSTALLATION

Made with FlippingBook flipbook maker