High Profile Trim
MVF-MVP Gable Ext Lead End w High Profile Trim-AP Soffit and Thermal Spacer
* NOTE: THIS FASTENER MUST NOT HIT THE PURLIN.
1
PURLIN
PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.
GABLE EXTENSION DIMENSION
PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)
CLOSURE CLIPS (GCC-1) (TYP.)
MVF/MVP ROOF PANEL PANEL CLIP w/FASTENERS
BL
PURLIN CLOSURE (TYP.)
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR) DOUBLE BEAD TAPE MASTIC * 1/4-14 X 7/8" WT (12" C.C.) (2) #12-14 X 1 1/4" (EACH CLIP) WALL COLOR PRE-GLUED THERMAL SPACER (NOT BY CHIEF)
GABLE TRIM (GTVH)
GABLE EXPANSION TRIM (GET) GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) #12-14 X 1 1/4" (12" C.C.) (TRIM COLOR) (2) 1/4-14 X 7/8" 1/4-14 X 7/8" (12" C.C.) GABLE EXTENSION CHANNEL (GEC) (2) #12-14 X 1 1/4" (WALL COLOR) PANEL CLIP #12-14 X 1 1/4" (12" C.C.) (SOFFIT COLOR) PANEL SUPPORT TRIM (SSP) (TYP.) #12-14 X 1" PANCAKE HEAD EACH PURLIN ** EXTENSION GABLE FLASHING (EGFA)
PURLIN
PURLIN CLOSURE (GPC)
PURLIN
THERMAL SPACER (NOT BY CHIEF)
(2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQUIRED)
(2) 1/8" X 3/8" BLIND RIVETS (TYP.)
(2) #12-14 X 1 1/4"' PER CLOSURE
TOP VIEW
#12-14 X 1 1/4" AT EACH PURLIN ROW (WALL COLOR)
NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.
AP SOFFIT PANEL
1/4-14 X 7/8" (12" C.C.) (SOFFIT COLOR)
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
EAVE STRUT
1/4-14 X 7/8" (12" C.C.)
INSIDE CLOSURE ***
JAMB TRIM (JT)
(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)
1/4-14 X 7/8" (12" C.C.)
1/4-14 X 7/8" (12" C.C.) PANEL CAP TRIM (SCT) RAKE ANGLE (A-20-B)
L OR H SYSTEM
TRIM TYPE EGFA EFHP
PURLIN SIZE
**
*** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.
8
HIGH HIGH
HIGH PROFILE TRIM-SOFFITED GABLE EXT MVF/MVP
10
PURLIN CLOSURE INSTALLATION
EGFA = EXTENSION GABLE FLASHING EFHP = EXT. FLASHING HIGH PROFILE