High Profile Trim

MVF-MVP Gable Ext Lead End w High Profile Trim-NO Soffit and Thermal Spacer

1

PURLIN

PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.

GABLE EXTENSION DIMENSION

PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)

CLOSURE CLIPS (GCC-1) (TYP.)

BL

PURLIN CLOSURE (TYP.)

DOUBLE BEAD TAPE MASTIC * 1/4-14 X 7/8" WT (12" C.C.) (2) #12-14 X 1 1/4" (EACH CLIP) WALL COLOR

* NOTE: THIS FASTENER MUST NOT HIT THE PURLIN. PANEL CLIP w/FASTENERS

GABLE TRIM (GTVH)

(2) #12-14 X 1 1/4" (WALL COLOR) PANEL CLIP

PURLIN

THERMAL SPACER

(NOT BY CHIEF)

#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)

PURLIN

GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) #12-14 X 1 1/4" (12" C.C.) (TRIM COLOR) (2) 1/4-14 X 7/8"

PRE-GLUED THERMAL SPACER (NOT BY CHIEF)

MVF/MVP ROOF PANEL PURLIN CLOSURE (GPC)

(2) 1/8" X 3/8" BLIND RIVETS (TYP.)

(2) #12-14 X 1 1/4"' PER CLOSURE

TOP VIEW

(2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQUIRED) #12-14 X 1" PANCAKE HEAD

GABLE EXPANSION TRIM (GET)

**

INSIDE CLOSURE

1/4-14 X 7/8" (12" C.C.) GABLE EXTENSION CHANNEL (GEC)

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) 1/4-14 X 7/8" (12" C.C.) PANEL CAP TRIM (SCT) RAKE ANGLE (A-20-B) FIELD NOTCH AS REQUIRED AT EACH PURLIN ROW

***

EXTENSION FLASHING (EF) #12-14 X 1" PANCAKE HEAD EACH PURLN #12-14 X 1 1/4" (12" C.C.)

NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.

EAVE STRUT

(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)

WALL PANEL

HIGH PROFILE TRIM- UNSOFFITED MVF/MVP ***

L OR H SYSTEM

TRIM TYPE

PURLIN SIZE

** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.

8

HIGH HIGH

EF

10

EFHP

PURLIN CLOSURE INSTALLATION

EF- EXTENSION FLASHING EFHP - EXT. FLASHING

Made with FlippingBook flipbook maker