MVF MVP Roof Panel

MVF-MVP Gable Lead End Height Change

* Field cut bottom of wall panels to match roof slope. Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

*WALL PANEL INSIDE CLOSURE #12-14 X 1 1/4"

HEIGHT CHANGE TRIM BOTTOM (GHVB) HEIGHT CHANGE TRIM TOP (GHVT)

BL

MVF/MVP ROOF PANEL DOUBLE BEAD TAPE MASTIC 1/4-14 X 7/8" WT (6" C.C.)** TAPE MASTIC (2) #12-14 X 1 1/4" (EACH CLIP) WALL COLOR PRE-GLUED THERMAL SPACER (NOT BY CHIEF)

(6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

***

1

4 "

RAKE ANGLE (A-20-L)

(2) #12-14 X 1 1/4"

PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)

1"

PANEL CLIP

**NOTE: This fastener must not hit the purlin. ***DRAFTING NOTE: Thermal spacer to be used with no insulation.

PURLIN

#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)