Special Features

Girt to Bypass Col w 6-8 Flange at Trans Exp

** Maintain 2 1/2" between fixed and sliding girt during building erection.

* Finger tighten 1st 1/2" dia. nut to hard washer, wrench tighten second nut to first nut to create a sliding connection. SPECIAL PUNCH 9/16" HOLES AT 1 3/8" DIM A AND 4 1/4" GAGE IN BOTH GIRTS

CL

ANGLE FLANGE BRACE (SEE CROSS SECTION FOR PIECE MARK AND BOLTING CONNECTION, INSTALL ONLY ON FIXED GIRT SIDE) FRAME COLUMN

* (2) 1/2" X 1 3/4" BOLTS w/ (2) NUTS AND (1) 1/2" HARD WASHER AT SLOT (BOLT MUST BE CENTERED IN SLOT)

3 1 4 "

**2 1 2 "

(4) 1/2" X 1 1/4" BOLTS

1 3 8 " 4 1 4 "

1 3 8 " 4 1 4 "

5 1 8 "

1 1 4 "

1 3 8 "

MAKE FROM BASE ANGLE COIL

BL

FIXED GIRT

SLIDING GIRT XBC-96

REF PT

(2) #12-14 X 1 1/4" (AT EACH GIRT) (WALL COLOR) SPECIAL RAKE ANGLE (PL- )

1 1 4 "

4 1 2 "