Special Features
Z-Purlin to Rafter 6-8 Flange and CS Roof Trans Exp
SPECIAL PUNCH 9/16" HOLES AT 1 3/8" DIM A AND 4 1/4" GAGE IN BOTH PURLINS
* Finger tighten 1st 1/2" dia. nut to hard washer, wrench tighten second nut to first nut to create a sliding connection. ** Maintain 2 1/2" between fixed and sliding purlin during building erection.
(2) #12-14 X 1 1/4" (AT EACH PURLIN) (WALL COLOR) SPECIAL RAKE ANGLE (PL- ) SLIDING PURLIN (4) 1/2" X 1 1/4" BOLTS
CL
1 1 4 "
4 1 2 "
REF PT
5 1 8 "
1 3 8 "
1 1 4 "
1 3 8 " 4 1 4 "
MAKE FROM BASE ANGLE COIL
XBC-96 * (2) 1/2" X 1 3/4" BOLTS w/ (2) NUTS AND (1) 1/2" HARD WASHER AT SLOT (BOLTS MUST BE CENTERED IN SLOT)
3 1 4 "
**2 1 2 "
FIXED PURLIN
ANGLE FLANGE BRACE (SEE CROSS SECTION FOR PIECE MARK AND BOLTING CONNECTION, INSTALL ONLY ON FIXED PURLIN SIDE)
FRAME RAFTER