Special Features
STC-MSC Gable Field Bend Vertical Leg - Taller Backup Panel and Thermal Spacer
** FIELD CUT BOTTOM OF BACK-UP PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.
SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING)
INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM
1
INSIDE CLOSURE
**BACK-UP PANEL
HEIGHT CHANGE TRIM TOP (GHMTF) TRI-BEAD TAPE SEALER SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING) (SEE INSET DETAIL)
BL
1/4-14 X 1 1/4" WT (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
RAKE SUPPORT (A-20-T)
1/4-14 X 1 1/4" WT (12" C.C.) STC/MSC ROOF PANEL (FIELD FORM 3" VERTICAL LEG TO FIT FINAL DIMENSION)
* It is important that fasteners are installed through the center of the slotted holes of the rake support. TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.
THERMAL SPACER
(NOT BY CHIEF)
1
4 "
HEIGHT CHANGE ANGLE (A-20-H)
HEIGHT CHANGE TRIM BOTTOM (GHMBF)
2"
1/4-14 X 1 1/4" SHOULDER (24" C.C.)*
#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN) PURLIN