Special Features
Extended Façade CS Roof Panel w Multi-gutter and Nichiha Panel-Cap Trim Not by Chief
DRAFTING: DIMENSION HORIZ. LEG OF CAP TRIM. HAVE PM VERIFY DIM. WITH BLDR.
HORIZONTAL LEG OF FASCIA CAP TRIM
1
* NOTE: CONNECTION OF NICHIHA PANELS (NOT BY CHIEF), TO WALL OR FASCIA PANEL IS NOT BY CHIEF.
TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.
BL
X'-X"
X"
CAP TRIM (NOT BY CHIEF) #12-14 X 1 1/4" (TYP) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
X
FASTENER (12" C.C.) (NOT BY CHIEF) 1/4-14 X 1 1/4" WT (6" C.C.)
XXX'-X"
OUTSIDE CLOSURE
INSIDE CLOSURE w/ TAPE MASTIC TOP AND BOTTOM 1/4-14 X 1 1/4" WT (6" C.C.) BACKUP PANEL
FASTENER (NOT BY CHIEF) (12" C.C.)
SPECIAL PURCHASED (IF BY CHIEF)
INSIDE CLOSURE W/ MASTIC TOP & BOTTOM
FACADE GIRT
GIRT
XXX'-X"
1/4-14 X 1 1/4" WT (4" C.C.) CS ROOF PANEL
* _" NICHIHA PANEL (NOT BY CHIEF)
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
FASCIA PANEL
** MULTI-GUTTER (MG-X)
EAVE STRUT
* _" NICHIHA PANEL (NOT BY CHIEF) WALL PANEL
** Refer to the Multi-Gutter Endcap and Splice detail for installation This run of multi-gutter uses (2) MGEC- as endcaps