Steel Framing Sections
5-13.Flange Brace XFBT-2 and XFBP-13 & XFBP-14 Double Angle Clips
NOTE: · Fill all holes in the flange brace with bolts. · If flange brace connection occurs within the purlin lap, install flange brace before tightening purlin bolts. · Flange brace may be one side only. For location and number of sides refer to Cross Sections, Endwall and Sidewall drawings.
RAFTER/COLUMN PURLIN/GIRT
BRACE DISTANCE
(4) 1/2" X 1 1/4" BOLTS (TYP) DOUBLE ANGLE FLANGE BRACE CLIP (XFBP-14)
DOUBLE ANGLE FLANGE BRACE CLIP (XFBP-13)
(3) 3/4" X 2" BOLT
FLANGE BRACE (FB-x)
3/4" X 2" BOLT
FLANGE BRACE "5-13 CONNECTION"