Wall Panel and Trim

CS Window or 4-Sided Opening w Jamb Trim-JT

CS Panel - Window Not by Chief or 4-Sided Opening with Sill Jamb Trim – JT

Header Trim (HTT) and Sill Trim (JT) lapped 3" min. past flat of Jamb Trim (JT). Flush with Cover Trim (COT).

Installation Steps: 1. Install Wrap Plate, if applicable. 2. Liner Cover Trim(LCT), if applicable. Use with Liner/Backer. Refer to Liner or Partition Panel Drawings. 3. Sill Jamb Trim (JT), slit and fold up at jamb. 4. Jamb Trim (JT) with notch at header. 5. Header Trim (HTT). 6. Notch and slit wall panel. 7. Place wall panel over trims with foam inside closures. 8. Cover Trim (COT). Notes: · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness.

2" JAMB TRIM NOTCH

2" X 1/4" PANEL NOTCH

1" PANEL SLIT

JAMB TRIM (JT) INSIDE CLOSURE HEADER TRIM (HTT)

LINER COVER TRIMS

For best weathertightness performance, JT/COT and Head/Sill Trim assembly should land in flat of panel. Layout, verify, and consider field locating framed opening as necessary. If this condition cannot be achieved, special field trim modifications, omitting COT trim, and/or additional urethane caulking Not By Chief may be required.

1" SLIT

2" X 1/4" NOTCH

3" TO FLAT OF JAMB TRIM

2" JAMB TRIM NOTCH

COVER TRIM (COT)

SILL JAMB TRIM (JT) NOTCH AND SLIT WALL PANEL FOR EXTENSION OF TRIM. (TYP.) **#12-14 X 1 1/4" (6" C.C.) (TYP.) WALL PANEL

Optional Urethane caulk around 1" panel slit and under COT (NOT BY CHIEF) (TYP.)

FLAT OF JAMB TRIM FLAT OF HEAD TRIM

WALL PANEL SLIT AND NOTCH (Typical at Sill)

TRIM DETAIL AT CORNERS

(Window not Shown)

ZEE GIRT #12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.) **#12-14 X 1 1/4" (6" C.C.)

BL

1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH LINER COVER TRIM (LCT)

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

LINER COVER TRIM (LCT1)

INSIDE CLOSURE

CEE HEADER

* 1 4 " * Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

1/8" X 3/8" BLIND RIVET, 18" C.C. WITH COVER TRIM (LCT)

OPENING WIDTH

JAMB 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)

HEADER TRIM (HTT)

LINER COVER TRIM (LCT2)

LINER COVER TRIM (LCT1)

SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL) LINER COVER TRIM (LCT2)

BL

**#12-14 X 1 1/4" (12" C.C.) WALL PANEL

JAMB TRIM (JT)

OPENING

CUT RIB AS NEEDED

1/8" X 3/8" BLIND RIVET, 18" C.C. WITH COVER TRIM (LCT)

1/8" X 3/8" BLIND RIVET (18" C.C.) (TYP.) COVER TRIM (COT)

SILL JAMB TRIM (JT)

INSIDE CLOSURE **#12-14 X 1 1/4" (6" C.C.)

GIRT/SILL

1/8" x 3/8" BLIND RIVET (7'-0" C.C.)

WALL PANEL (TYP.)

OPENING DETAILS AT HEADER AND SILL

FRAMED OPENING DETAILS AT JAMB

Made with FlippingBook - professional solution for displaying marketing and sales documents online