Composite Material, Rigid Board, R-Seal
CS Rigid Roof-Wall High Side
NOTES: * See isometric detail "PIGTAIL TAPE MASTIC INSTALLATION WITH HIGH SIDE EAVE TRIM". ** Insulation is representative. Erector shall refer to insulation manufacturer’s installation information for further details/direction. The erector is responsible for providing the final solution for installation, air tightness, and performance of the liner insulation system.
CS ROOF PANEL
1/4-14 X 7/8" WT (12" C.C.)
TAPE MASTIC ON TOP OF CLOSURE
HIGHSIDE EAVE TRIM (HSEC)
1/4-14 X 7/8" WT (12" C.C.)
TAPE MASTIC AT PANEL LAP
#12-14 X ___" (6" C.C.)
BL
1 1
* OUTSIDE CLOSURE w/ TAPE MASTIC TOP AND BOTTOM
2 "
INSIDE CLOSURE
PANEL OVERHANG FROM INSUL.
1/4-14 X 7/8" (12" C.C.) HI-SIDE EAVE TRIM (HSEC)
CS ROOF PANEL
WALL PANEL
CS INSIDE CLOSURE
CS OUTSIDE CLOSURE
1"
TOP OF PURLIN
TAPE MASTIC ON BOTTOM OF CLOSURE
EAVE STRUT ** ___" RIGID CONTINUOUS INSULATION (NOT BY CHIEF)
EAVE
HEIGHT
SPECIAL TRIM CAP (SPT-x)
PIGTAIL TAPE MASTIC (Install a "Pig Tail" down the bearing leg of panel to form a continuous line of tape mastic with panel lap and closure.)
#12-14 X ___" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
INSIDE CLOSURE
EAVE MEMBER
OUTSIDE CLOSURE 1/4-14 X 7/8" (12" C.C.)
TRIM CAP (TCH)
WALL PANEL
** ___" RIGID CONTINUOUS INSULATION (NOT BY CHIEF)
PIGTAIL TAPE MASTIC INSTALLATION WITH HIGH SIDE EAVE TRIM ≤ 2:12
(Rigid Insulation Not Shown)