Composite Material, Rigid Board, R-Seal

STC-MSC Deck Rigid Roof-Wall Low Side Gutter

NOTES: * Field cut (2) 2" long strips of tri-bead tape mastic & center under 1/4-14 X 7/8" WT's between gutter strap and roof panel. ** See Isometric Trapezoid Plug Installation detail for installation instructions. *** Insulation is representative. Erector shall refer to insulation manufacturer’s installation information for further details/direction. The erector is responsible for providing the final solution for installation, air tightness, and performance of the liner insulation system. **** See Roof Deck Fastener Details for additional fastener spacing information.

1/4-14 X 7/8" WT (6" C.C.) **TRAPEZOID PLUG (TRP) EACH HIGH RIB TRI-BEAD TAPE MASTIC (TOP AND BOTTOM) DOUBLE BEAD TAPE MASTIC (TOP AND BOTTOM) GUTTER STRAP (GSM) AT EACH PANEL HI-RIB

STC/MSC ROOF PANEL 1/4-14 X 1" (2) PER CLOSURE METAL INSIDE CLOSURE *(2) 1/4-14 X 7/8" WT GUTTER STRAP TO ROOF PANEL 2" STRIP OF TRI-BEAD TAPE MASTIC BETWEEN PANELS 1/4-14 X 1 1/4" WT PANEL TO EAVE (8 PER PANEL)

BL

x"

GUTTER STRAP LAP

4 1

2 "

PANEL OVERHANG FROM INSUL.

#12-14 X 1 1/4" (TRIM COLOR)

Top of Eave Angle to be installed 3/8" above top of insulation.

EAVE GUTTER (EGM)

TOP OF INSULATION

EAVE ANGLE

TOP OF PURLIN *** ___" RIGID CONTINUOUS INSULATION (NOT BY CHIEF)

1"

(2) #12-14 X 1" PANCAKE HEAD (2'-0" C.C.)

TOP OF PURLIN

EAVE STRUT

DECKING

EAVE

EAVE STRUT

HEIGHT

**** ___ X ___ (___" C.C.)

#12-14 X ____" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) 1/4-14 X 7/8" (12" C.C.) TRIM CAP (TCM) INSIDE CLOSURE

EAVE ANGLE (PL-x)

EAVE ANGLE CONNECTION DRAFTING NOTE: 3/8" is for MSC/STC LOW Clip option ONLY.

*** ___" RIGID CONTINUOUS INSULATION (NOT BY CHIEF) (2) #12-14 X 1" PANCAKE HEAD (2'-0" C.C.)

DRAFTING NOTE: Include Corresponding Standard Details. - STC-MSC Eave Isometric

WALL PANEL

Made with FlippingBook Annual report maker