Composite Material, Rigid Board, R-Seal

STC-MSC Deck Rigid Roof-Wall High Side

NOTES: * For screw spacing refer to High Eave Trim detail in the STC/MSC Roof Panel Erection Manual. ** 24" STC - Pre-Cut Tri-Bead Tape Mastic. 24" MSC - Tri-Bead Tape Mastic from roll. 18" STC/MSC - Tri-Bead Tape Mastic from roll. *** Insulation is representative. Erector shall refer to insulation manufacturer’s installation information for further details/direction. The erector is responsible for providing the final solution for installation, air tightness, and performance of the liner insulation system. **** See Roof Deck Fastener Details for additional fastener spacing information.

TRI-BEAD TAPE MASTIC *1/4-14 X 7/8" WT

BACK-UP PLATE **TRI-BEAD TAPE MASTIC 1/4-14 X 1 1/4" WT (9 PER PANEL) OUTSIDE CLOSURE

BL

PANEL CLIP W/ FASTENERS (SEE ROOF PANEL PLAN) PRE-GLUED THERMAL SPACER (NOT BY CHIEF) BEARING PLATE (HW7500)

2 3 4 " PANEL OVERHANG FROM INSUL.

HI-SIDE EAVE TRIM (HSEMC)

OUTSIDE CLOSURE

STC/MSC ROOF PANEL

1"

TOP OF PURLIN

DECKING

EAVE STRUT *** ___" RIGID CONTINUOUS INSULATION (NOT BY CHIEF) **** ___ X ___ (___" C.C.)

EAVE

HEIGHT

1/4-14 X 7/8" (12" C.C.) 1/4-14 X 7/8" (12" C.C.)

JAMB TRIM

*** ___" RIGID CONTINUOUS INSULATION (NOT BY CHIEF)

#12-14 X ____" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

INSIDE CLOSURE

WALL PANEL