Composite Material, Rigid Board, R-Seal

STC-MSC Rigid Roof-Wall Eave Ext High Side CS-AP Soffit

NOTES: * For screw spacing refer to High Eave Trim detail in the STC/MSC Roof Panel Erection Manual. ** 24" STC - Pre-Cut Tri-Bead Tape Mastic. 24" MSC - Tri-Bead Tape Mastic from roll. 18" STC/MSC - Tri-Bead Tape Mastic from roll.. ***Insulation is representative. Erector shall refer to insulation manufacturer’s installation information for further details/direction. The erector is responsible for providing the final solution for installation, air tightness, and performance of the liner insulation system.

DRAFTING NOTES: If intermediate purlin is required, chg purlin, t-spacer and all fasteners to "dim" layer.

*1/4-14 X 7/8" WT TRI-BEAD TAPE MASTIC

1/4-14 X 1 1/4" WT (9 PER PANEL) OUTSIDE CLOSURE

PRE-GLUED THERMAL SPACER FOR EAVE EXTENSION

BL

PANEL CLIP W/ FASTENERS (SEE ROOF PANEL PLAN) (TYP.)

3 1

2 "

(NOT BY CHIEF)

PRE-GLUED THERMAL SPACER (NOT BY CHIEF)

PANEL OVERHANG FROM EXT. PURLIN

STC/MSC ROOF PANEL SPECIAL PLATE (PL-x)

**TRI-BEAD TAPE MASTIC

BACK-UP PLATE

PRE-GLUED THERMAL SPACER (NOT BY CHIEF) BEARING PLATE (HW7500)

#12-14 X 1 1/4" (12" C.C.) (TRIM COLOR)

TOP OF PURLIN

HI-SIDE EAVE TRIM (HSEMC)

INTERMED. PURLIN

*** ___" RIGID CONTINUOUS INSULATION (NOT BY CHIEF)

1"

1/4-14 X 7/8" (12" C.C.) HIGH SIDE EXTENSION FLASHING (SPT-x)

#12-14 X _____" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) INSIDE CLOSURE

EAVE HEIGHT

*** ___" RIGID CONTINUOUS INSULATION (NOT BY CHIEF)

1/4-14 X 7/8" (12" C.C.)

SOFFIT PANEL

SOFFIT TRIM (ESTA) 1/4-14 X 7/8" (12" C.C.) WALL PANEL OUTSIDE CLOSURE 1/4-14 X 7/8" (12" C.C.) (SOFFIT COLOR)

#12-14 X 1 1/4" (12" C.C.)

OUTSIDE CLOSURE