Composite Material, Rigid Board, R-Seal
STC-MSC Rigid Roof-Wall Gable Tail
NOTES: * It is important that 1/4-14 X 1 1/4" SHOULDER fasteners are installed through the center of the slotted holes of the rake support. ** Field cut outside closure for higher roof pitches. *** Insulation is representative. Erector shall refer to insulation manufacturer’s installation information for further details/direction. The erector is responsible for providing the final solution for installation, air tightness, and performance of the liner insulation system.
1/4-14 X 1 1/4" WT (12" C.C.) TRI-BEAD TAPE SEALER *1/4-14 X 1 1/4" SHOULDER (24" C.C.) STC/MSC ROOF PANEL PRE-GLUED THERMAL SPACER (NOT BY CHIEF) 1/4-14 X ____" W/O (2 EACH PURLIN)
RAKE SUPPORT (A-20-S) GABLE TRIM (SPT-x)
BL
ROOF PANEL SUPPORT (A-20-L)
(2) 1/4-14 X 7/8"
#12-14 X ____" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
INSIDE CLOSURE
**OUTSIDE CLOSURE WALL PANEL 1/4-14 X 7/8" (12" C.C.) GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) GABLE EXPANSION TRIM (GET)
*** ___" RIGID CONTINUOUS INSULATION (NOT BY CHIEF) #12-14 X 1" PANCAKE HEAD (2 EACH PURLIN)
RAKE ANGLE (A-20-B)
PURLIN
*** ___" RIGID CONTINUOUS INSULATION (NOT BY CHIEF)