Composite Material, Rigid Board, R-Seal

STC-MSC Rigid Roof-Wall Gable Ext Lead

NOTES: * It is important that 1/4-14 X 1 1/4" SHOULDER fasteners are installed through the center of the slotted holes of the rake support. ** Insulation is representative. Erector shall refer to insulation manufacturer’s installation information for further details/direction. The erector is responsible for providing the final solution for installation, air tightness, and performance of the liner insulation system.

PURLIN

PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.

PURLIN CLOSURE (GPC2 OR GPC3) (TYP.) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)

CLOSURE CLIPS (GCC-1) (TYP.)

PURLIN CLOSURE (TYP.)

PURLIN

BL

GABLE EXTENSION DIMENSION

(2) 1/8" X 3/8" BLIND RIVETS (TYP.)

STC/MSC ROOF PANEL PANEL CLIP w/FASTENERS (SEE ROOF PANEL PLAN)

TRI-BEAD TAPE SEALER 1/4-14 X 1 1/4" WT (12" C.C.)

(2) #12-14 X 1 1/4"' PER CLOSURE

* 1/4-14 X 1 1/4" SHOULDER (24" C.C.)

#12-14 X 1 1/4" (12" C.C.) (TRIM COLOR) GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) (2) 1/4-14 X 7/8" SPECIAL ANGLE (PL-x) RAKE SUPPORT (A-20-S) GABLE TRIM (GTMC)

PURLIN

TOP VIEW

#12-14 X 1" PANCAKE HEAD (2 PER PURLIN)

PRE-GLUED THERMAL SPACER

PRE-GLUED THERMAL SPACER FOR GABLE EXTENSION

#12-14 X _____" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) RAKE ANGLE (A-20-B) (Optional. Mirror Rake Angle #12-14 X 1 1/4" AT EACH PURLIN ROW (WALL COLOR) orientation to avoid insulation break depending on girt/frame orientation.) (2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE PURLIN CLOSURE (GPC) INSULATION (NOT BY CHIEF) ** ___" RIGID CONTINUOUS INSULATION (NOT BY CHIEF) PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQ'D) (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN

NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.

INSUL.

DEPTH

SPECIAL PLATE (PL-x) (TYP.)

EAVE STRUT

1/4-14 X 7/8" (12" C.C.) GABLE EXPANSION TRIM (GET)

(2)1/4-14 X 1" (2'-0" C.C.) (TYP.)

(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)

1/4-14 X 7/8" (12" C.C.) (SOFFIT COLOR) AP SOFFIT PANEL

GABLE EXTENSION CHANNEL (GEC) EXTENSION FLASHING (SPT-x)

PURLIN CLOSURE INSTALLATION

PANEL SUPPORT TRIM (SSP) 1/4-14 X 7/8"(12" C.C.)

#12-14 X 1 1/4" (12" C.C.) (SOFFIT COLOR)

JAMB TRIM (JT)

#12-14 X 1 1/4" (PANCAKE HEAD EACH PURLIN) PANEL SUPPORT TRIM (SSP) 1/4-14 X 7/8" (12" C.C.)

1/4-14 X 7/8 (12" C.C.) PANEL CAP TRIM (SCT) INSIDE CLOSURE

WALL PANEL

** ___" RIGID CONTINUOUS INSULATION (NOT BY CHIEF)