Composite Material, Rigid Board, R-Seal

STC-MSC Deck Rigid Roof-Wall High Side Height Change

NOTES: * For screw spacing refer to High Side Height Change detail in the MSC/STC Roof Panel Erection Manual.

INSIDE CLOSURE WALL PANEL

BL

** 24" STC - Pre-Cut Tri-Bead Tape Mastic. 24" MSC - Tri-Bead Tape Mastic from roll. 18" MSC/STC - Tri-Bead Tape Mastic from roll.

#12-14 X _____" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

***Provide air gap of 1/4" min. at bottom of panel to avoid corrosion. **** Insulation is representative. Erector shall refer to insulation manufacturer’s installation information for further details/direction. The erector is responsible for providing the final solution for installation, air tightness, and performance of the liner insulation system. *****See Roof Deck Fastener Details for additional fastener spacing information.

STC/MSC ROOF PANEL BEARING PLATE (HW7500) PRE-GLUED THERMAL SPACER **TRI-BEAD TAPE MASTIC OUTSIDE CLOSURE 1/4-14 X 1 1/4" WT (9 PER PANEL) TRI-BEAD TAPE MASTIC *1/4-14 X 7/8" WT HEIGHT CHANGE TRIM (LHET) PANEL CLIP W/ FASTENERS (SEE ROOF PANEL PLAN)

*** 1 4 "

HEIGHT CHANGE GIRT

3 3/4"

DRAFTING NOTE: Include Corresponding Standard Details. - STC-MSC Height Change Isometric Details

(NOT BY CHIEF)

#12-14 X 1" PANCAKE HEAD (48" C.C.)

**** ___" RIGID CONTINUOUS INSULATION (NOT BY CHIEF)

x"

DECKING

SPECIAL TRIM (SPT-x) (PW)

**** ___" RIGID CONTINUOUS INSULATION (NOT BY CHIEF)

#12-14 X 1" PANCAKE HEAD (48" C.C.)

BACK-UP PLATE

4"

8"

***** ___ X ___ (___" C.C.)

INSULATION TO PANEL

PURLIN

Made with FlippingBook Annual report maker