Composite Material, Rigid Board, R-Seal
STC Deck Rigid Roof Panel Splice Low
1/4-14 X 1 1/4" WT
3" NOTCH TO AVOID INTERFERENCE W/ BACK-UP PLATE FASTENERS
ROOF PANEL SUPPORT
FIELD LOCATED FASTENERS
1 1 2 "
5
7"
1"
1/4-14 X 1 1/4" WT (9 PER PANEL) STC ROOF PANEL
3"
4"
1
4 8 3 9 2
PURLIN LINE
6
7
RAKE SUPPORT ROOF PANEL SUPPORT
3" Notch 4"
FIELD LOCATED FASTENERS
1/4-14 X 1 1/4" WT
*TRI-BEAD TAPE MASTIC STC ROOF PANEL BACKER PLATE
DECKING
RIGID CONTINUOUS INSULATION (NOT BY CHIEF)
ROOF PANEL SUPPORT ANGLE NOTCH AT SPLICE
**SEE ROOF PANEL PLAN
BEARING PLATE (HW7500)
RIGID CONTINUOUS INSULATION (NOT BY CHIEF)
IMPORTANT: Apply TRI-BEAD tape mastic over the notched portion of these male legs.
DECKING
PURLIN
* 24" STC - Pre-Cut Tri-Bead Tape Mastic. 18" STC - Tri-Bead Tape Mastic from roll. ** Roof Paneling Plan for roof panel clip, panel clip fastener and thermal spacer requirements.
Follow the instructions for sequences and usage that are in the manual-adding the 2 field located 1/4-14 X 1 1/4" WTs as the last step.
STC ROOF PANEL SPLICE DETAIL W/ RIGID CONTINUOUS INSULATION AND DECKING
Made with FlippingBook Annual report maker