Composite Material, Rigid Board, R-Seal

Brittle Material at Panel Rigid Wall

Reference notes: · Use 1/8" X 3/8" Blind Rivets 10'-0" C.C. to attach Base Trim to Base Member. · Drill Ø1/8" hole for 1/8" X 3/8" Blind Rivets. · Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

* ___" RIGID CONTINUOUS INSULATION (NOT BY CHIEF)

BL

INSIDE CLOSURE WALL PANEL

#12-14 X 1" PANCAKE HEAD (12" C.C.)

#12-14 X _____" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

MASTIC (NOT BY CHIEF) BASE MEMBER (Refer to Sidewall and Endwall Drawings for Base Member Type and Anchor Rod Drawings for Anchorage)

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

SEE ELEVATION DRAWINGS

1

4 "

1 1 2 "

BASE TRIM (BTNT) SPECIAL TRIM (SPT-x) R-SEAL BASE CHANNEL (NOT BY CHIEF) Notes:

BRITTLE MATERIAL WALL (NOT BY CHIEF)

Y1

* Insulation is representative. Erector shall refer to insulation manufacturer’s installation information for further details/direction. The erector is responsible for providing the final solution for installation, air tightness, and performance of the insulation system.

Made with FlippingBook Annual report maker