Eave Ext Horiz Soff Low Steel - Bypass Rafter Greater than 1'-2 w Soffit Angle Left
EAVE STRUT FRAME COLUMN EAVE EXTENSION BEAM
* (2) #12-14 X 1 1/4" ON TOP AND (1) #12-14 X 1 1/4" ON BOTTOM (WALL COLOR) HOLD 1" DISTANCE ON CS ROOF PANEL, ON STC/MSC ROOF PANEL USE (2) #12-14 X 1" PANCAKE HEAD ON TOP. NOTE: EAVE STRUT AND EAVE EXTENSION BEAM CONNECTIONS PER GENERAL DETAIL PAGES. TALLER EAVE STRUT AND EXTENSION PURLIN ARE USED ON STANDING SEAM ROOFS. XLGA-1 BETWEEN INTERMEDIATE PURLIN / CHANNEL AND FASTENERS NOT SHOWN.
INTERMEDIATE PURLIN (2) XBC-__ (6) 1/2" X 1 1/4" BOLTS
1
BL
XBC-33 (4) 1/2" X 1 1/4" BOLTS
2 "
1 1
GABLE EXTENSION CHANNEL (GEC )
1
BOLTING CLIPS (NOT SHOWN) INTERMEDIATE PURLIN
EAVE EXTENSION PURLIN
BL
SPECIAL ANGLE (PL- ) ( ) #12-14 X 1 1/4" (___" C.C.)
(4) #12-14 X 1 1/4" GIRT ANGLE (XGA-__)
*1"
SPECIAL ANGLE (PL- )
EAVE EXTENSION PROJECTION
( ) #12-14 X 1 1/4" (___" C.C.)
#12-14 X 1 1/4"
XXX' - X"
EAVE EXTENSION BEAM GIRT ANGLE (XGA- )
SOFFIT RAKE ANGLE ( )
#12-14 X 1" PANCAKE HEAD (24" C.C.)
SECTION
#12-14 X 1" PANCAKE HEAD