Eave and Gable Extensions
Eave Ext Horiz Soff Low Gable Ext - FSP Soffit Bypass Gable and CS Roof High Pitch
Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
REFER TO GABLE SECTIONS FOR ROOF PANEL AND GABLE TRIM ATTACHMENTS AT THE BUILDING GABLE. *** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.
* (2) #12-14 X 1 1/4" ON TOP AND (1) #12-14 X 1 1/4" ON BOTTOM (WALL COLOR) HOLD 1" DISTANCE
1
GABLE EXTENSION CHANNEL (GEC )
INSIDE CLOSURE
***
INTERMEDIATE PURLIN
BL
#12-14 X 1 1/4"(TYP) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
* 1"
EAVE EXTENSION END PANEL
#12-14 X 1" PANCAKE HEAD (24" C.C.)
SOFFIT PURLIN
SOFFIT RAKE ANGLE (A-20-H)
** INSIDE CLOSURE
XXX' - X"
1
4 "
EAVE EXTENSION BEAM (2) #12-14 X 1 1/4" GIRT ANGLE (XGA- )
SOFFIT TRIM (VPST)
1/8" X 3/8" BLIND RIVET (12" C.C.) PANEL SUPPORT (SSSP)
FSP SOFFIT PANEL
**DRAFTING: INSIDE CLOSURE NOT REQ'D IF WALLS ARE "CS INSULATED"
#12-14 X 1" PANCAKE HEAD (12" C.C.) (TYP.)