Eave and Gable Extensions

LS Eave Ext Only - Horiz FSP Soffit Bypass Gable and CS Roof Panel High Pitch

Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

REFER TO GABLE SECTIONS FOR ROOF PANEL AND GABLE TRIM ATTACHMENTS AT THE BUILDING GABLE. *** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.

* (2) #12-14 X 1 1/4" ON TOP AND (1) #12-14 X 1 1/4" ON BOTTOM (WALL COLOR) HOLD 1" DISTANCE

1

GABLE EXTENSION CHANNEL (GEC )

INSIDE CLOSURE

***

INTERMEDIATE PURLIN

BL

#12-14 X 1 1/4"(TYP) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

* 1"

EAVE EXTENSION END PANEL

#12-14 X 1" PANCAKE HEAD (24" C.C.)

SOFFIT PURLIN

SOFFIT RAKE ANGLE (A-20-H)

INSIDE CLOSURE **

XXX' - X"

1

4 "

EAVE EXTENSION BEAM (2) #12-14 X 1 1/4" GIRT ANGLE (XGA- )

SOFFIT TRIM (VPST)

1/8" X 3/8" BLIND RIVET (12" C.C.) PANEL SUPPORT (SSSP)

FSP SOFFIT PANEL

**DRAFTING: INSIDE CLOSURE NOT REQ'D IF WALLS ARE "CS INSULATED"

#12-14 X 1" PANCAKE HEAD (12" C.C.) (TYP.)