Eave Ext Horiz Soff Low CS - FSP Soffit w Eave Gutter
1
BL
CS ROOF PANEL * 1/4-14 X 1 1/4" WT (__" C.C.) (TYP.) * 12" C.C. NON UL 6" C.C. UL 90
(1) 1/4-14 X 7/8" (TRIM COLOR) GUTTER STRAP (GS) (___" C.C.) 1/4-14 X 7/8" WT (6" C.C.) INSIDE CLOSURE WITH TAPE MASTIC TOP & BOTTOM
1/4-14 X 1 1/4" WT (6" C.C.) (2) 1/4-14 X 7/8" WT EACH GUTTER STRAP INSIDE CLOSURE
8 11
16 "
1/4-14 X 1 1/4" WT (6" C.C.)
8 "
2 7
EAVE STRUT
SOFFIT PURLIN
EAVE GUTTER (EGA)
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
(2) 1/4-14 X 1 1/4" WT EACH GUTTER STRAP
INSIDE CLOSURE **
#12-14 X 1 1/4" (12" C.C.) (TRIM COLOR) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
OUTSIDE CLOSURE INTERMEDIATE PURLIN
TRIM CAP (TC_)
SPECIAL TRIM (SPT- ) EAVE EXTENSION PURLIN
1/4-14 X 7/8" (12" C.C.) (SOFFIT COLOR)
#12-14 X 1" PANCAKE HEAD (12" C.C.) (TYP.) FSP SOFFIT PANEL
SOFFIT TRIM (SBLTA)
1/8" X 3/8" BLIND RIVET (12" C.C.)
WALL PANEL
NOTE: 26 GA FSP SOFFIT MUST HAVE 1/4-14 X 7/8" FASTENERS AT HI-RIB, LOCATED AT SUPPORTS AND MID-SPAN BETWEEN SUPPORTS. SHOW AND CALL OUT FASTENER IF REQUIRED.
NOTE: SOFFIT PURLIN SHOWN REMOVE IF NOT USED. TURN SPECIAL ANGLE FASTENER & TEXT TO BE VISIBLE.
SPECIAL ANGLE (PL )
** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.