Eave and Gable Extensions

LS Eave Ext Only - Horiz FSP Soffit - STC-MSC w Eave Gutter

1

PRE-GLUED THERMAL SPACER (NOT BY CHIEF)

1/4-14 X 1" (2) PER CLOSURE METAL INSIDE CLOSURE (2) 1/4-14 X 7/8" WT GUTTER STRAP TO ROOF PANEL

BL

* SEE ADJACENT DETAIL FOR INSTALLATION OF TRAPEZOID PLUG (TRP) ** FIELD CUT (2) 2" LONG STRIPS OF TRI-BEAD TAPE SEALER. CENTER UNDER 1/4-14 X 7/8" WT FASTENERS BETWEEN GUTTER STRAP AND ROOF PANEL. *** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM. NOTE: 26 GA FSP SOFFIT MUST HAVE 1/4-14 X 7/8" FASTENERS AT HI-RIB, LOCATED AT SUPPORTS AND MID-SPAN BETWEEN SUPPORTS. SHOW AND CALL OUT FASTENER IF REQUIRED. NOTE: SOFFIT PURLIN SHOWN REMOVE IF NOT USED. TURN SPECIAL ANGLE FASTENER & TEXT TO BE VISIBLE.

PANEL CLIP WITH FASTENERS

1/4-14 X 1 1/4" WT (8 PER PANEL)

STC/MSC ROOF PANEL

3 3

DOUBLE BEAD TAPE MASTIC * TRAPEZOID PLUG (TRP) EACH HIGH RIB TRI-BEAD TAPE SEALER

8 "

1/4-14 X 1 1/4" WT (6 PER PANEL)

** 2" STRIP TRI-BEAD TAPE SEALER (TYP.)

EAVE STRUT

GUTTER STRAP (GSM) AT EACH PANEL HI-RIB

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

#12-14 X 1 1/4" (TRIM COLOR)

INSIDE CLOSURE

***

EAVE GUTTER (EGM) 1/4-14 X 7/8" WT 6" C.C.)

1/4-14 X 7/8" (12" C.C.) (SOFFIT COLOR) OUTSIDE CLOSURE

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

#12-14 X 1 1/4" (12" C.C.) (TRIM COLOR)

SOFFIT PURLIN

INTERMEDIATE PURLIN

FSP SOFFIT PANEL

TRIM CAP (TC_)

SOFFIT TRIM (SBLTA)

#12-14 X 1" PANCAKE HEAD (12" C.C.) (TYP.) EAVE EXTENSION PURLIN

SPECIAL TRIM (SPT- ) 1/8" X 3/8" BLIND RIVET (12" C.C.) (TYP.)

WALL PANEL

SPECIAL ANGLE (PL )