Eave and Gable Extensions

LS Eave Ext Only - Horiz FSP Soffit - STC-MSC w Oversize Eave Gutter and Thermal Spacer

1

PANEL CLIP WITH FASTENERS

* SEE ADJACENT DETAIL FOR INSTALLATION OF TRAPEZOID PLUG (TRP) ** FIELD CUT (2) 2" LONG STRIPS OF TRI-BEAD TAPE SEALER. CENTER UNDER 1/4-14 X 7/8" WT FASTENERS BETWEEN GUTTER STRAP AND ROOF PANEL. *** FIELD DRILL 1/4" DIA. HOLE IN GUTTER STRAP, FIELD DRILL 1/8" DIA. PILOT HOLE IN FLAT STRAP IF REQUIRED. **** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM. NOTE: 26 GA FSP SOFFIT MUST HAVE 1/4-14 X 7/8" FASTENERS AT HI-RIB, LOCATED AT SUPPORTS AND MID-SPAN BETWEEN SUPPORTS. SHOW AND CALL OUT FASTENER IF REQUIRED. NOTE: SOFFIT PURLIN SHOWN REMOVE IF NOT USED. TURN SPECIAL ANGLE FASTENER & TEXT TO BE VISIBLE.

** 2" STRIP TRI-BEAD TAPE SEALER (TYP.)

1/4-14 X 1 1/4" WT (8 PER PANEL)

BL

PRE-GLUED THERMAL SPACER (NOT BY CHIEF)

DOUBLE BEAD TAPE MASTIC * TRAPEZOID PLUG (TRP) EACH HIGH RIB TRI-BEAD TAPE SEALER

1/4-14 X 1" (2) PER CLOSURE METAL INSIDE CLOSURE (2) 1/4-14 X 7/8" WT GUTTER STRAP TO ROOF PANEL

STC/MSC ROOF PANEL

3 3

8 "

1/4-14 X 1 1/4" WT (6 PER PANEL)

GUTTER STRAP (GSM) AT EACH PANEL HI-RIB

EAVE STRUT

FLAT STRAP (PL- ) *** 1/4-14 X 1" (EACH STRAP)

#12-14 X 1 1/4 (TRIM COLOR)

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

SPECIAL EAVE GUTTER (SPT- ) 1/4-14 X 7/8" WT (6" C.C.) 1/4-14 x 1 1/4" WT (AT STRAP LOCATIONS)

1/4-14 X 7/8" (12" C.C.) (SOFFIT COLOR) OUTSIDE CLOSURE INTERMEDIATE PURLIN INSIDE CLOSURE **** SOFFIT TRIM (SBLTA)

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

SOFFIT PURLIN

#12-14 X 1" PANCAKE HEAD (12" C.C.) (TYP.) 1/8" X 3/8" BLIND RIVET (12" C.C.) (TYP.) FSP SOFFIT PANEL

#12-14 X 1 1/4" (12" C.C.) (TRIM COLOR)

WALL PANEL

TRIM CAP (TC_)

SPECIAL ANGLE (PL )

SPECIAL TRIM (SPT- ) EAVE EXTENSION PURLIN