Eave and Gable Extensions
CS Gable Ext AP Soffit
PURLIN
PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.
PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)
CLOSURE CLIPS (GCC-1) (TYP.)
1
CS ROOF PANEL
PURLIN CLOSURE (TYP.)
GABLE EXTENSION DIMENSION
PURLIN
BL
#12-14 X 1 1/4" (12" C.C.) (TRIM COLOR) #12-14 X 1 1/4" (2 PER PURLIN) (WALL COLOR)
1/4-14 X 7/8" WT (12" C.C.) DOUBLE BEAD TAPE MASTIC #12-14 X 1" PANCAKE HEAD EACH PURLIN
PURLIN CLOSURE (GPC)
2 1 8 "
PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQUIRED) (2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN
PURLIN
GABLE TRIM (GTC)
(2) 1/8" X 3/8" BLIND RIVETS (TYP.)
1/4-14 X 7/8" (12" C.C.)
(2) #12-14 X 1 1/4"' PER CLOSURE
1"
GABLE EXTENSION CHANNEL (GEC)
TOP VIEW
#12-14 X 1 1/4"(12" C.C.) (SOFFIT COLOR) EXTENSION FLASHING (EF) PANEL SUPPORT TRIM (SSP)
#12-14 X 1 1/4" AT EACH PURLIN ROW (WALL COLOR)
1/4-14 X 7/8" (12" C.C.) (SOFFIT COLOR) AP SOFFIT PANEL
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.
1/4-14 X 7/8" (12" C.C.) PANEL SUPPORT TRIM (SSP)
1/4-14 X 7/8" (12" C.C.)
INSIDE CLOSURE *
EAVE STRUT
JAMB TRIM (JT)
RAKE ANGLE (A-20-B) 1/4-14 X 7/8" (12" C.C.) PANEL CAP TRIM (SCT) WALL PANEL
(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)
* DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.
PURLIN CLOSURE INSTALLATION