Eave and Gable Extensions
CS Gable Ext NO Soffit
PURLIN
PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.
PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)
1
CLOSURE CLIPS (GCC-1) (TYP.)
PURLIN CLOSURE (TYP.)
GABLE EXTENSION DIMENSION
RAKE ANGLE (A-20-B) FIELD NOTCH AS REQUIRED AT EACH PURLIN ROW (2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN * DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM. #12-14 X 1" PANCAKE HEAD (EACH PURLIN) PURLIN CLOSURE (GPC) PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQUIRED)
BL
1/4-14 X 7/8" WT (12" C.C.) DOUBLE BEAD TAPE MASTIC
#12-14 X 1 1/4" (2 PER PURLIN) (WALL COLOR) #12-14 X 1 1/4" (12" C.C.) (TRIM COLOR)
2 1 8 "
CS ROOF PANEL
PURLIN
PURLIN
GABLE TRIM (GTC)
(2) 1/8" X 3/8" BLIND RIVETS (TYP.)
1"
1/4-14 X 7/8" (12" C.C.)
(2) #12-14 X 1 1/4"' PER CLOSURE
INSIDE CLOSURE *
TOP VIEW
GABLE EXTENSION CHANNEL (GEC)
PANEL CAP TRIM (SCT) 1/4-14 X 7/8" (12" C.C.) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
EXTENSION FLASHING (EF)
#12-14 X 1" PANCAKE HEAD EACH PURLIN #12-14 X 1 1/4" (12" C.C.)
NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.
WALL PANEL
EAVE STRUT
(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)
PURLIN CLOSURE INSTALLATION
Made with FlippingBook flipbook maker