Eave and Gable Extensions

STC-MSC Low Side Eave Ext w Oversize Gutter and CS-AP Soffit and Thermal Spacer

1/4-14 X 1 1/4" WT (8 PER PANEL)

1/4-14 X 7/8" WT (6" C.C.) (1/4-14 X 1" AT STRAP LOCATION) DOUBLE BEAD TAPE MASTIC (TOP AND BOTTOM) * TRAPEZOID PLUG (TRP) AT EACH HIGH RIB ** (2) 1/4-14 X 7/8" WT GUTTER STRAP TO ROOF PANEL

PRE-GLUED THERMAL SPACER FOR EAVE EXTENSION (NOT BY CHIEF) PANEL CLIP W/ FASTENERS (SEE ROOF PANEL PLAN)

BL

METAL INSIDE CLOSURE TRI-BEAD TAPE MASTIC (TOP AND BOTTOM) 2" STRIP OF TRI-BEAD TAPE MASTIC BETWEEN PANELS

STC/MSC ROOF PANEL

1/4-14 X 1 1/4" WT (6 PER PANEL)

GUTTER STRAP (GSM) AT PANEL HI-RIBS #12-14 X 1 1/4" (EACH STRAP) (TRIM COLOR)

INTERMED. PURLIN *****

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

*** 1/4-14 X 1" (EACH STRAP)

FLAT STRAP (GSMO-)

EAVE EXTENSION FLASHING (EEFA)

OUTSIDE CLOSURE INSIDE CLOSURE ****

#12-14 X 1 1/4" (12" C.C.) (TRIM COLOR)

1/4-14 X 7/8" (12" C.C.) (SOFFIT COLOR) SOFFIT TRIM (ESTO) 1/4-14 X 7/8" (12" C.C.) WALL PANEL

#12-14 X 1 1/4" (12" C.C.) SOFFIT PANEL 1/4-14 X 1" (2 PER CLOSURE)

OVERSIZE GUTTER (SPT- )

1/4-14 X 7/8" (12" C.C.)

PANEL OVERHANG

GUTTER STRAP LAP

PITCH

EXTENSION FLASHING (EF)

<=3/4:12 >3/4:12 to <=1 1/2:12 >1 1/2:12 to <=2 1/2:12 >2 1/2:12 to <=3 1/2:12 >3 1/2:12 to <=4 1/2:12 ALL DIMENSIONS IN INCHES 4 1/2 3 1/2 3 1/2 4 4 1/4

7 7/8 7 1/2

1/4-14 X 7/8" (12" C.C.)

OUTSIDE CLOSURE

7 1/8

** Field cut (2) 2" long strips of tri-bead tape mastic & center under 1/4-14 x 7/8" WT's between gutter strap and roof panel. * See isometric Trapezoid Plug Installation detail for installation instructions.

6 7/16

5 3/4

DRAFTING NOTES: **** Inside closure must be provided on buildings with liner insulation system. ***** If intermediate purlin is required, chg purlin, t-spacer and all fasteners to "dim" layer.

*** Field drill 1/4" dia. hole in gutter strap, field drill 1/8" dia. pilot hole in flat strap if required.