Eave and Gable Extensions
STC-MSC High Side Eave Ext w Eave Trim and NO Soffit and Thermal Spacer
*1/4-14 X 7/8" WT TRI-BEAD TAPE MASTIC
1/4-14 X 1 1/4" WT (9 PER PANEL) OUTSIDE CLOSURE **TRI-BEAD TAPE MASTIC
STC/MSC ROOF PANEL *** TRAPEZOID PLUG (TRP) AT EACH HI-RIB PRE-GLUED THERMAL SPACER FOR EAVE EXTENSION
(NOT BY CHIEF)
BL
3 1 2 "
PANEL CLIP W/ FASTENERS (SEE ROOF PANEL PLAN) (TYP)
PRE-GLUED THERMAL SPACER
(NOT BY CHIEF)
BACK-UP PLATE
THERMAL SPACER
(NOT BY CHIEF)
HI-SIDE EAVE TRIM (HSEMC)
INTERMED. PURLIN *****
1/8" X 3/8" BLIND RIVET (PARCHMENT) (2 PER PLUG)
1/4-14 X 7/8" (12" C.C.) HIGH SIDE EXTENSION FLASHING (HEEF)
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
#12-14 X 1 1/4" (12" C.C.) (TRIM COLOR)
DRAFTING NOTES: **** Inside closure must be provided on buildings with liner insulation system. ***** If intermediate purlin is required, chg purlin, t-spacer and all fasteners to "dim" layer.
I*N**S* IDE CLOSURE
1/4-14 X 7/8" (12" C.C.)
NOTE: Jamb trim around extension beam as required. * For screw spacing refer to High Eave Trim detail in the STC/MSC Roof Panel Erection Manual. ** 24" STC - Pre-Cut Tri-Bead Tape Mastic. 24" MSC - Tri-Bead Tape Mastic from roll. 18" STC/MSC - Tri-Bead Tape Mastic from roll. *** See isometric Trapezoid Plug Installation detail for installation instructions.
PANEL CAP TRIM (SCT)
WALL PANEL
Made with FlippingBook flipbook maker