Eave and Gable Extensions

STC-MSC Gable Ext Tail End w AP Soffit

***DRAFTING NOTE: THERMAL SPACER TO BE USED WITH NO INSULATION

1

PURLIN

PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.

PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)

CLOSURE CLIPS (GCC-1) (TYP.)

PURLIN CLOSURE (TYP.)

BL

PANEL CLIP W/FASTENERS

GABLE EXTENSION DIMENSION

#12-14 X 1 1/4" (12" C.C.) (SOFFIT COLOR) EXTENSION FLASHING (EF) PANEL SUPPORT TRIM (SSP) 1/4-14 X 7/8" (12" C.C.) #12-14 X 1 1/4" (12" C.C.) (TRIM COLOR) RAKE SUPPORT (A-20-S) GABLE TRIM (GTM) #12-14 X 1" PANCAKE HEAD (2 PER PURLIN) GABLE EXPANSION TRIM (GET) GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) GABLE EXTENSION CHANNEL (GEC) 1/4-14 X 7/8" (12" C.C.) (2) 1/4-14 X 7/8"

PURLIN

STC/MSC ROOF PANEL * 1/4-14 X 1 1/4" SHOULDER (24" C.C.) TRI-BEAD TAPE SEALER 1/4-14 X 1 1/4" WT (12" C.C.)

PRE-GLUED THERMAL SPACER FOR GABLE EXTENSION (NOT BY CHIEF) PRE-GLUED THERMAL SPACER *** (NOT BY CHIEF)

PURLIN

PURLIN CLOSURE (GPC)

(2) 1/8" X 3/8" BLIND RIVETS (TYP.)

#12-14 X 1 1/4" AT EACH PURLIN ROW (WALL COLOR) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQ'D) (2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN

(2) #12-14 X 1 1/4"' PER CLOSURE

TOP VIEW

AP SOFFIT PANEL

NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.

1/4-14 X 7/8" (12" C.C.) (SOFFIT COLOR)

PANEL SUPPORT TRIM (SSP) 1/4-14 X 7/8" (12" C.C.)

INSIDE CLOSURE **

EAVE STRUT

1/4-14 X 7/8" (12" C.C.) RAKE ANGLE (A-20-B) PANEL CAP TRIM (SCT)

(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)

JAMB TRIM (JT)

#12-14 X 1" PANCAKE HEAD EACH PURLIN

** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.

* NOTE: IT IS IMPORTANT THAT 1/4-14 X 1 1/4" SHOULDER FASTENERS ARE INSTALLED THROUGH THE CENTER OF THE SLOTTED HOLES OF THE RAKE SUPPORT.

WALL PANEL

PURLIN CLOSURE INSTALLATION

Made with FlippingBook flipbook maker