Eave and Gable Extensions

STC-MSC Gable Ext Tail End-Termination Trim w FSP Soffit

DRAFTING NOTES: ** Field cut around purlins for attachment. *** Inside closure must be provided on buildings with liner insulation system. **** Thermal spacer to be used with no insulation. ***** 26 GA FSP soffit must always have 1/4-14 x 7/8" fasteners located at ribs at end supports. change fasteners to "dim" layer.

****** If sub-framing at gable extension exceeds 4'-0 spacing then an A-20 angle will be sent and field cut around purlins for attachment. fasteners for angle to purlin and soffit to angle will be sent. change angle and fasteners to "dim" layer.

PURLIN

PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.

PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)

CLOSURE CLIPS (GCC-1) (TYP.)

PANEL CLIP w/FASTENERS (TYP) PURLIN STC/MSC ROOF PANEL

PURLIN CLOSURE (TYP.)

BL

******

GABLE EXTENSION DIMENSION

TRI-BEAD TAPE MASTIC 1/4-14 X 1 1/4" WT (12" C.C. AND FASTEN THROUGH CLIP) TERMINATION TRIM (GTTM) RAKE SUPPORT (A-20-S) 1/4-14 X 1 1/4" WT (24" C.C.)

TRI-BEAD TAPE MASTIC 1/4-14 X 7/8" WT (6" C.C.)

#12-14 x 1 1/4" AT EACH PURLIN ROW (WALL COLOR) #12-14 x 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) (2) #12-14 x 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQ'D) (2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE PURLIN CLOSURE (GPC) PRE-GLUED THERMAL SPACER FOR GABLE EXTENSION (NOT BY CHIEF) PRE-GLUED THERMAL SPACER **** (NOT BY CHIEF)

PURLIN

#12-14 x 1 1/4" (12" C.C.) (TRIM COLOR) * 1/4-14 X 1 1/4" SHOULDER (24" C.C.) GABLE TRIM (GTM)

(2) 1/8" X 3/8" BLIND RIVETS (TYP.)

** RAKE ANGLE (A-20)

(2) #12-14 X 1 1/4"' PER CLOSURE

#12-14 X 1" PANCAKE HEAD (2 PER PURLIN)

TOP VIEW

1/4-14 X 7/8" (EACH RIB) (SOFFIT COLOR)

(2) 1/4-14 X 7/8"

GABLE TRIM SUPPORT (GTS) (10'-0" C.C.)

GABLE EXPANSION TRIM (GET)

#12-14 X 1" PANCAKE HEAD (12" C.C.) (TYP.)

1/4-14 X 7/8" (12" C.C.)

NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.

#12-14 X 1" PANCAKE HEAD (AT EACH PURLIN PRIOR TO SOFFIT INSTALLATION) EXTENSION FLASHING (EF) GABLE EXTENSION CHANNEL (GEC)

1/4-14 X 7/8" (EACH RIB) (SOFFIT COLOR)

*****

1/8" X 3/8" BLIND RIVET (12" C.C.) #12-14 X 1" PANCAKE HEAD (AT EACH PURLIN PRIOR TO SOFFIT INSTALLATION) (TYP.) JAMB TRIM/SOFFIT TRIM (JTS)

EAVE STRUT

(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)

INSIDE CLOSURE ***

FSP SOFFIT PANEL 1/8" X 3/8" BLIND RIVET (12" C.C.)

1/4-14 X 7/8" (12" C.C.) PANEL CAP TRIM (SCT) RAKE ANGLE (A-20-B)

PURLIN CLOSURE INSTALLATION

* It is important that 1/4-14 x 1 1/4" SHOULDER fasteners are installed through the center of the slotted holes of the rake support.

WALL PANEL