Eave and Gable Extensions

STC-MSC Gable Ext Tail End -Field Bend Vertical Leg-Term Trim w AP Soffit and Thermal Spacer

1

PURLIN

GABLE EXTENSION DIMENSION

PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.

PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)

CLOSURE CLIPS (GCC-1) (TYP.)

TRI-BEAD TAPE SEALER 1/4-14 X 7/8" WT (6" C.C.) TERMINATION TRIM (GTTM) 1/4-14 X 1 1/4" WT (24" C.C.) NOTE: FIELD FORM A 3" VERTICAL ROOF PANEL LEG TO FIT FINAL DIMENSION

BL

TRI-BEAD TAPE SEALER 1/4-14 1 1/4" WT (12" C.C.) * 1/4-14 X 1 1 /4" SHOULDER (24" C.C.) RAKE ANGLE (A-20-B) #12-14 X 1" PANCAKE HEAD (2) PER PURLIN) RAKE SUPPORT (A-20-T) PRE-GLUED THERMAL SPACER FOR GABLE EXTENSION (NOT BY CHIEF)

PURLIN CLOSURE (TYP.)

* NOTE: IT IS IMPORTANT THAT 1/4-14 X 1 1/4" SHOULDER FASTENERS ARE INSTALLED THROUGH THE CENTER OF THE SLOTTED HOLES OF THE RAKE SUPPORT.

PURLIN

PANEL CLIP w/FASTENERS STC/MSC ROOF PANEL

(2) 1/8" X 3/8" BLIND RIVETS (TYP.)

GABLE TRIM (GTM)

PURLIN THERMAL SPACER

(NOT BY CHIEF)

(2) #12-14 X 1 1/4"' PER CLOSURE

RAKE SUPPORT (A-20-T)

* 1/4-14 X 1 1/4" SHOULDER(24" C.C.)

PURLIN CLOSURE (GPC)

#12-14 X 1 1/4" (12" C.C.) (TRIM COLOR) #12-14 X 1" PANCAKE HEAD (2 PER PURLIN)

PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQ'D) (2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN #12-14 X 1 1/4" AT EACH PURLIN ROW (WALL COLOR)

TOP VIEW

(2) 1/4-14 X 7/8"

GABLE TRIM SUPPORT (GTS) 10'-0" C.C.)

NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.

GABLE EXPANSION TRIM (GET)

AP SOFFIT PANEL

GABLE EXTENSION CHANNEL (GEC) 1/4-14 X 7/8" (12" C.C.)

EAVE STRUT

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

PANEL SUPPORT TRIM (SSP) (TYP.) 1/4-14 X 7/8" (12" C.C. (TYP.) 1/4-14 X 7/8" (12" C.C.) (SOFFIT COLOR) JAMB TRIM (JT)

(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)

#12-14 X 1 1/4" (12" C.C.) (SOFFIT COLOR) EXTENSION FLASHING (EF)

INSIDE CLOSURE **

1/4-14 X 7/8" (12" C.C.) PANEL CAP TRIM (SCT) RAKE ANGLE (A-20-B)

WALL PANEL

** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.

#12-14 X 1" PANCAKE HEAD EACH PURLIN

PURLIN CLOSURE INSTALLATION

Made with FlippingBook flipbook maker