Eave and Gable Extensions
STC-MSC Gable Ext Tail End -Field Bend Vertical Leg-Term Trim w NO Soffit and Thermal Spacer
PURLIN
PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.
PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)
GABLE EXTENSION DIMENSION
TRI-BEAD TAPE SEALER 1/4-14 X 7/8" WT (6" C.C.) TERMINATION TRIM (GTTM) 1/4-14 X 1 1/4" WT (24" C.C.) NOTE: FIELD FORM A 3" VERTICAL ROOF PANEL LEG TO FIT FINAL DIMENSION
CLOSURE CLIPS (GCC-1) (TYP.)
PURLIN CLOSURE (TYP.)
BL
TRI-BEAD TAPE SEALER 1/4-14 X 1 1/4" WT (12" C.C.) * 1/4-14 X 1 1/4" SHOULDER (24" C.C.) #12-14 X 1" PANCAKE HEAD (2 PER PURLIN) RAKE SUPPORT (A-20-T)
* NOTE: It is important that 1/4-14 X 1 1/4" SHOULDER fasteners are installed through the center of the slotted holes of the rake support.
PURLIN STC/MSC ROOF PANEL THERMAL SPACER PURLIN CLOSURE (GPC) PANEL CLIP w/FASTENERS (SEE ROOF PANEL PLAN)
PURLIN
(2) 1/8" X 3/8" BLIND RIVETS (TYP.)
* 1/4-14 X 1 1/4" SHOULDER (24" C.C.) RAKE SUPPORT (A-20-T) GABLE TRIM (GTMC)
RAKE ANGLE (A-20-B)
(2) #12-14 X 1 1/4"' PER CLOSURE
(NOT BY CHIEF)
TOP VIEW
RAKE ANGLE (A-20-B) FIELD NOTCH AS REQUIRED AT EACH PURLIN ROW #12-14 X 1" PANCAKE HEAD (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQ'D) (2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE
#12-14 X 1" PANCAKE HEAD (2 PER PURLIN) #12-14 X 1 1/4" (12" C.C.) (TRIM COLOR)
**
INSIDE CLOSURE
(2) 1/4-14 X 7/8"
NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.
GABLE TRIM SUPPORT (GTS) (10'-0" C.C.)
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C.for AP PANEL) 1/4-14 X 7/8" (12" C.C.) PANEL CAP TRIM (SCT)
GABLE EXPANSION TRIM (GET)
1/4-14 X 7/8" (12" C.C.)
EAVE STRUT
GABLE EXTENSION CHANNEL (GEC)
(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)
#12-14 X 1" PANCAKE HEAD EACH PURLIN
PRE-GLUED THERMAL SPACER FOR GABLE EXTENSION (NOT BY CHIEF)
WALL PANEL
#12-14 X 1 1/4" (12" C.C.) EXTENSION FLASHING (EF)
** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.
PURLIN CLOSURE INSTALLATION
Made with FlippingBook flipbook maker